6 / 18 page Corporation SIGNAL PROCESSING EXCELLENCE 56 isolate an SP301/302 from ground in the power- off condition. With V DD turned on, the transistor switch is on, connecting ground (GND) for the device to the circuit ground. In a power-off condition, this transistor is switched off, thus isolating the unit from circuit ground, and thereby leaving the driver in a high impedance state. Multiple SP301/302s can be connected as shown in Figure 1b. RS-422 OPERATION The SP301 and SP302 are fully compliant RS-422 devices when operating in the RS-422 mode. Baud rate and drive capability have been balanced to provide as much versatility as pos- sible. The SP301 and SP302 are both guaran- teed for a 1Mbps data rate, supplying ±2V minimum into a 100 Ω load. Short circuit protec- tion for the RS-422 operating mode is the same as in the RS-232 mode. The driver outputs can be shorted to ground for an infinite duration, with a maximum current of ±100mA. The RS-422 receivers accept differential signals at a 1Mbps rate, and translate them to a non- inverted TTL output. The receivers are speci- fied with a ±15V differential input voltage, which means that to operate normally, the dif- ference betweeen the voltages at the inputs cannot exceed ±15V. The common mode volt- age is specified as ±7V. This identifies the midpoint of the range about which the differen- tial input must lie so that the receiver can detect a change of state. Within this ±7V range, the receivers will recognize a change in state with a ±200mV differential threshold voltage. Since the RS-232 and RS-422 inputs are shared, all receiver inputs are protected to ±30V to guard against inadvertently applying an RS-232 signal to an input that is configured for RS-422. Figure 2 shows a typical circuit for the SP301/302. In this case the SP302 is shown configured for one (1) duplex RS-422 and two (2) duplex RS-232 communication paths. CONFIGURING THE SP301/302 Figures 3, 5 and 6 show the various combina- tions of simultaneous RS-232 and RS-422 op- eration that can be achieved with the SP301. Similarly, Figures 4, 7 and 8 show the various combinations for the SP302. Each of these con- figurations are software selectable by logic level on the SELECT A and SELECT B control lines. Configuration can be changed “on-the-fly”. |
Similar Part No. - SP301CS |
|
Similar Description - SP301CS |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |