Electronic Components Datasheet Search
  English  ▼

Delete All
ON OFF
ALLDATASHEET.COM

X  

Preview PDF Download HTML

HD74LVCC4245A Datasheet(PDF) 3 Page - Renesas Technology Corp

Part No. HD74LVCC4245A
Description  Octal Dual-supply Bus Transceiver with configurable output voltage with 3-state Outputs
Download  11 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Maker  RENESAS [Renesas Technology Corp]
Homepage  http://www.renesas.com
Logo RENESAS - Renesas Technology Corp

HD74LVCC4245A Datasheet(HTML) 3 Page - Renesas Technology Corp

  HD74LVCC4245A Datasheet HTML 1Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 2Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 3Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 4Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 5Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 6Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 7Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 8Page - Renesas Technology Corp HD74LVCC4245A Datasheet HTML 9Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 3 / 11 page
background image
HD74LVCC4245A
Rev.1.00 Aug. 23, 2004 page 3 of 10
Absolute Maximum Ratings
Item
Symbol
Ratings
Unit
Conditions
Supply voltage
VCCA, VCCB
–0.5 to 6.0
V
Input voltage
*1
VI
–0.5 to 6.0
V
DIR,
OE
–0.5 to VCCA+0.5
A port output “H” or “L”
–0.5 to 6.0
A port output “Z” or VCCA : OFF
–0.5 to VCCB+0.5
B port output “H” or “L”
Input / output voltage
VI/O
–0.5 to 6.0
V
B port output “Z” or VCCB : OFF
Input diode current
IIK
–50
mA
VI < 0
–50
VO < 0
Output diode current
IOK
50
mA
VO > VCC+0.5
Output current
IO
±50
mA
VCCA, VCCB, GND current
ICCA, ICCB, IGND 100
mA
Maximum power dissipation
at Ta = 25°C (in still air)
*2
PT
862
mW
TSSOP
Storage temperature
Tstg
–65 to 150
°C
Notes:
The absolute maximum ratings are values, which must not individually be exceeded, and furthermore, no two
of which may be realized at the same time.
1. The input and output voltage ratings may be exceeded even if the input and output clamp-current ratings are
observed.
2. The maximum package power dissipation was calculated using a junction temperature of 150°C.
Recommended Operating Conditions
Item
Symbol
Ratings
Unit
Conditions
VCCA
4.5 to 5.5
Supply voltage
VCCB
2.7 to 5.5
V
VI
0 to 5.5
DIR,
OE
0 to VCCA
A port output “H” or “L”
0 to 5.5
A port output “Z” or VCCA : OFF
0 to VCCB
B port output “H” or “L”
Input / output voltage
VI/O
0 to 5.5
V
B port output “Z” or VCCB : OFF
IOH
–24
output current
IOL
24
mA
Input transition rise or fall time
∆t / ∆v
10
ns / V
Operating temperature
Ta
–40 to 85
°C
Note:
Unused or floating inputs must be held high or low.


Html Pages

1  2  3  4  5  6  7  8  9  10  11 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn