11 / 17 page
11
TECHNICAL DATA
LD1207
APLICATIONS
Display memory is updated by incrementing addresses. Please refer to the following diagram.
Command1
Command2
Command3
Data1
Data2
Command4
---------------------
---------------------
STB
CLK
DIN
Where : Command 1 : Display Mode Setting
Command 2 : Data Setting Command
Command 3 : Address Setting Command
Data 1 to n : Transfer Display Data (14 Bytes max.)
Command 4 : Display Control Command
The following diagram shows the waveforms when updating specific addresses.
command2
command3
Data
command3
Data
STB
DIN
CLK
Where : Command 2 -- Data Setting Command
Command 3 -- Address Setting Command
Data -- Display Data