Electronic Components Datasheet Search |
|
BYT115 Datasheet(PDF) 3 Page - Vishay Siliconix |
|
BYT115 Datasheet(HTML) 3 Page - Vishay Siliconix |
3 / 5 page ![]() BYT115/200/400 Vishay Telefunken Rev. A2, 24-Jun-98 3 (5) 0 0.6 1.2 1.8 2.4 0.01 0.1 1 10 100 VF – Forward Voltage ( V ) 3.0 94 9509 Figure 3. Typ. Forward Current vs. Forward Voltage 0 0 200 400 600 800 1000 94 9515 3 6 12 18 21 15 9 IF – Forward Current ( A ) dIF/dt=150A/ms Figure 4. Reverse Recovery Charge vs. Forward Current 0 50 100 200 300 0 40 80 120 160 –dIF/dt – Forward Current Rate of Change ( A/ms ) 350 94 9514 250 150 Figure 5. Reverse Recovery Time for IRM vs. Forward Current Rate of Change 0 94 9513 5 10 15 20 0 50 100 200 300 –dIF/dt – Forward Current Rate of Change ( A/ms ) 350 250 150 Figure 6. Reverse Recovery Current vs. Forward Current Rate of Change 0 50 100 150 200 250 94 9512 0 50 100 200 300 –dIF/dt – Forward Current Rate of Change ( A/ms ) 350 250 150 Figure 7. Reverse Recovery Time vs. Forward Current Rate of Change 0 200 400 600 800 1200 94 9511 1000 0 50 100 200 300 –dIF/dt – Forward Current Rate of Change ( A/ms ) 350 250 150 Figure 8. Reverse Recovery Charge vs. Forward Current Rate of Change |