Electronic Components Datasheet Search |
|
DR2260A30WRJ Datasheet(PDF) 1 Page - Crydom Inc., |
|
DR2260A30WRJ Datasheet(HTML) 1 Page - Crydom Inc., |
1 / 2 page Do not forget to visit us at: www.crydom.com Copyright © 2016 Crydom Inc. Specifications subject to change without notice. Installation Sheet DIN Rail Mount DR22 Series Solid State Relays Crydom DR22 Series Solid State Relays were developed to offer the advantages of semiconductor switching technology in a standard 22.5 mm industrial package. Quick and easy installation is coupled with low drive power requirements and efficient, reliable power SCR output. This compact new design offers up to 35 ARMS in ambient temperatures of 40ºC. Be sure to visit the product series datasheet available at the Crydom website to complement this information. If you have questions or need additional information please contact Crydom Tech Support. Please read all instructions before using your DIN Rail Mount Solid State Relay (SSR). MOUNTING INSTRUCTIONS fig. 1 SSR mounted on DIN rail To install on DIN rail To remove from DIN rail ■Install the relay on the DIN Rail (as shown in fig. 1) ■Maximum recommended terminal screw torque input terminal: ♦Contactor configuration (”V” & “W” suffixes): 5 in-lb (0.5 Nm) ♦Relay configuration (”U” suffix): 13-15 in-lb (1.5-1.7 Nm) ■Maximum recommended terminal screw torque load terminal: ■ If multiple units are installed be sure to follow derating curves ■ Recommended wire sizes as shown in TABLE 1 WARNING! Removing product from 35 mm rail incorrectly by not using the appropriate tool would damage the latching system. ♦Contactor configuration (”V” & “W” suffixes): 18-20 in-lb (2.0-2.2 Nm) ♦Relay configuration (”U” suffix): 13-15 in-lb (1.5-1.7 Nm) Required for valid part number For options only and not required for valid part number Operating Voltage 20: 1-200 VDC 60: 48-600 VAC Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (AC Output only) Control Voltage A: 90-280 VAC/VDC (AC Output only) D: 4-32 VDC Series DR22 60 A R Rated Load Current 20: 20 Amps 30: 30 Amps 35: 35 Amps [High I2 t] (AC Output only) U Terminal Layout U: Relay Configuration V: Contactor Configuration (std. screw) W: Contactor Configuration (elevator screw) Input Connector Blank: Screw Terminal J: Spring Terminal (V and W suffixes only) V 20 J AC Output only PART NUMBER NOMENCLATURE ■ Important Considerations ♦ Be sure to use input and output voltages within operating ranges. ♦ LED indicates only input status. It does not represent output status. ♦ To achieve maximum ratings, there must be a minimum spacing of 0.89 in (22.5 mm) between the devices in free air (as shown in fig.2). ♦ Protective Earth (PE) screw type recommended is 10-32 UNC standard, not provided with SSR. Through the use of a DIN rail ground (protective conductor) terminal block, the DIN rail itself can be used as the grounding bus bar. In this case, the zinc plated steel material used for the DIN rail clip of DR22 models, permits a secure path to ground and avoid the need of a further PE connection (see fig.3). 0.89 in [22.5 mm] Minimum (A) (B) WIRING DIAGRAMS -4/A2 +3/A1 -2 +1 INPUT STATUS 1/L1 2/T1 INPUT STATUS -4/A2 +3/A1 -4/A2 +3/A1 2/T1 1/L1 INPUT STATUS V AC Load Relay AC Contactor AC Relay DC + - + Load V AC Load V (+) (-) (+ / ) (- / ) (+ / ) (- / ) Lug Terminal ID Marker TABLE 3. Recommended Accessories CNLB CNLN CNL2 Connectors CP201 CP202 TRM0 TRM6 TABLE 2. Compatible Terminals Fork Lug Ring Lug Copper Lug Copper Lug Width [W] in (mm) Terminals Stud Size Dia [D] (in) Wire Size AWG Crydom Part No. 0.45 (11.4) #8 (0.168) 0.45 (11.4) #8 (0.168) TRM0 6-0 TRM6 14-6 W D W D TABLE 1. Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb)[N]* Output Relay “U” suffix Input Relay “U” suffix Output Contactor “V” &“W” suffixes Input Contactor “V” &“W” suffixes 2 x 18 AWG (1 mm2) Stranded [minimum] 2 x 10 AWG (6 mm2) Stranded [maximum] 2 x 18 AWG (1 mm2) Stranded 2 x 12 AWG (4 mm2) Stranded 2 x 20 AWG (0.75 mm2) [minimum] 2 x 10 AWG (6 mm2) 2 x 8 AWG (10 mm2) [maximum] 30 AWG (0.05 mm2) [minimum] 12 AWG (3.3 mm2) [maximum] 26 AWG (0.13 mm2) [minimum] 12 AWG (3.3 mm2) [maximum] 20 [88] 60 [266] 20 [88] 40 [177] 25 [111] 80 [355] 90 [400] 4.5 [20] 30 [133] 5 [22] 5 [22] Screw Spring * Tests performed on Stranded wire General Notes (A) Load can be wired to either terminal 1 or terminal 2. Proper polarity must be observed for the DC control power supply, with terminal 3 being positive with respect to terminal 4. (B) DC inductive loads must be diode suppressed. (C) AC input models operating range is -20 to 60 ºC Rev. 060816 fig. 2 Multiple units mounting for maximum ratings fig. 3 DR22 model with Protective Earth screw |
Similar Part No. - DR2260A30WRJ |
|
Similar Description - DR2260A30WRJ |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |