1 / 7 page DataSheet DIN Rail Mount SeriesOne DR Series ATEX • Ratings 3 Amps • Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC • Fits standard 35mm DIN Rail • LED input status indicator • AC or DC control • Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output • UL 508 Endurance Rating for Enhanced Reliability • UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280V, 3 A 600V, 3 A 60V, 3 A 100V, 3 A 4-32 VDC DR10D03X 90-140 VAC 200-280 VAC AVAILABLE OPTIONS OUTPUT SPECIFICATIONS AC Output (2) Description DR24x03X DR48x03X DR06D03X DR10D03X Operating Voltage (3) 24-280 Vrms 48-600 Vrms 1-60 VDC 1-100 VDC Transient Overvoltage [Vpk] 600 1200 N/A N/A Maximum Load Current, resistive (4) 3 Arms 3 Arms 3 3 150 mArms 150 mArms 2.5 mAdc 2.5 mAdc 0.1 0.1 0.1 0.1 Minimum Load Current 500 500 N/A N/A Maximum Surge Current (50/60Hz, 1 cycle) [Apk] 1.3 1.3 0.6 0.6 Maximum On-State Voltage Drop @ Rated Current [Vpk] 285/300 285/300 60 60 410/375 410/375 N/A N/A Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec] 1/4 (.18) 1/4 (.18) N/A N/A N/A 1/3 (.25) N/A N/A 18-36 VAC DR24D03X DR24B03X DR24A03X DR48D03X DR06D03X DR24E03X Maximum Off-State Leakage Current @ Rated Voltage [mA] Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ µsec] (5) HP Rating UL 508/IEC60947 [HP (KW)] @ 240V Minimum Power Factor (at Maximum Load) Min/Max stranded wire HP Rating UL 508/IEC60947 [HP (KW)] @ 380V HP Rating UL 508/IEC60947 [HP (KW)] @ 480V Min/Max solid wire Weight (Typical) N/A N/A 1/2 (.37) N/A 0.5 0.5 N/A N/A 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) AC Output Only Series Operating Voltage 06: 1-60 VDC 10: 1-100 VDC 24: 24-280 VAC 48: 48-600 VAC Rated Load Current 03: 3 Amps Control Voltage D: 4-32 VDC A: 200-265 VAC B: 90-140 VAC E: 18-36 VAC (1) 03 06 D DR X Agency Approvals X: ATEX II 3G Ex nA IIC T4 Gc approved Switching Type Blank: Zero Voltage Turn-On (AC Output Only) R: Instantaneous Turn-On (AC Output) R Required for valid part number For options only and not required for valid part number Do not forget to visit us at: www.crydom.com Copyright © 2017 Crydom Inc. Specifications subject to change without notice. DC AC |
Similar Part No. - DR06E03XR |
|
Similar Description - DR06E03XR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |