9 / 16 page ![]() Ref.CE-P3415 04/16 5. Reliability 5-1. Reliability Test 5-2. Failure Criteria 9 ( Tc=25C ) U defines the upper limit of the specified characteristics. S defines the initial value. Note : Measurement shall be taken between 2 hours and 24 hours, and the test pieces should be return to the normal ambient conditions after the completion of each test. Total Luminous Flux Φv IF =350mA <S × 0.8 Measuring Item Symbol Measuring Condition Failure Criteria Power Dissipation VF IF =350mA >U × 1.2 -30 C × 30 minutes – 85 C × 30 minutes, 100 cycle Tc=85C, 95 %RH for 500 hours Thermal Shock Test High Temperature Storage Test Low Temperature Storage Test Moisture-proof Test IF =350mA , Tc=85C Continuous Operation Test Test Item Ta = 100 C × 1000 hours Ta = -40 C × 1000 hours Test Condition |
|