5 / 16 page Data Sheet ADuM4121/ADuM4121-1 Rev. 0 | Page 5 of 16 INSULATION AND SAFETY-RELATED SPECIFICATIONS Table 4. Parameter Symbol Value Unit Conditions Rated Dielectric Insulation Voltage 5000 V rms 1-minute duration Minimum External Air Gap (Clearance) L(I01) 8 min mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 8 min mm Measured from input terminals to output terminals, shortest distance path along body Minimum Clearance in the Plane of the Printed Circuit Board (PCB Clearance) L (PCB) 8.3 min mm Measured from input terminals to output terminals, shortest distance through air, line of sight, in the PCB mounting plane Minimum Internal Gap (Internal Clearance) 25.5 min µm Minimum distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >400 V DIN IEC 112/VDE 0303 Part 3 Isolation Group II Material Group (DIN VDE 0110, 1/89, Table 1) DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS This isolator is suitable for reinforced isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits. Table 5. VDE Characteristics Description Test Conditions/Comments Symbol Characteristic Unit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 600 V rms I to IV Climatic Classification 40/105/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage VIORM 849 V peak Input to Output Test Voltage, Method B1 VIORM × 1.875 = Vpd (m), 100% production test, tini = tm = 1 sec, partial discharge < 5 pC Vpd (m) 1592 V peak Input to Output Test Voltage, Method A After Environmental Tests Subgroup 1 VIORM × 1.5 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC Vpd (m) 1274 V peak After Input and/or Safety Test Subgroup 2 and Subgroup 3 VIORM × 1.2 = Vpd(m), tini = 60 sec, tm = 10 sec, partial discharge < 5 pC Vpd (m) 1019 V peak Highest Allowable Overvoltage VIOTM 7000 V peak Surge Isolation Voltage Basic VPEAK = 16 kV, 1.2 µs rise time, 50 µs, 50% fall time VIOSM 16,000 V peak Surge Isolation Voltage Reinforced VPEAK = 16 kV, 1.2 µs rise time, 50 µs, 50% fall time VIOSM 10,000 V peak Safety Limiting Values Maximum value allowed in the event of a failure (see Figure 2) Maximum Junction Temperature TS 150 °C Safety Total Dissipated Power PS 1.2 W Insulation Resistance at TS VIO = 500 V RS >109 Ω Figure 2. Thermal Derating Curve, Dependence of Safety Limiting Values on Case Temperature, per DIN V VDE V 0884-10 RECOMMENDED OPERATING CONDITIONS Table 6. Parameter Value Operating Temperature Range (TJ) −40°C to +125°C Supply Voltages VDD1 to GND1 2.5 V to 6.5 V VDD2 to GND2 4.5 V to 35 V 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 50 100 150 200 AMBIENT TEMPERATURE (°C) |
Similar Part No. - ADuM4121-1BRIZ-RL |
|
Similar Description - ADuM4121-1BRIZ-RL |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |