Electronic Components Datasheet Search |
|
BQ57120QEX50 Datasheet(PDF) 5 Page - SynQor Worldwide Headquarters |
|
BQ57120QEX50 Datasheet(HTML) 5 Page - SynQor Worldwide Headquarters |
5 / 14 page Product # BQ57120QEx50 Phone 1-888-567-9596 www.synqor.com Doc.# 005-0006201 Rev. C 07/21/15 Page 5 Technical Specification Input: 40-65 V Output: 9.3-16.25 V Current: 50A Package: Quarter-brick BQ57120QEx50 Electrical Characteristics (continued) Ta = 25 °C, airflow rate = 300 LFM, Vin = 52.5 V dc unless otherwise noted; full operating temperature range is -40 °C to +100 °C ambient temperature with appropriate power derating. Specifications subject to change without notice. Parameter Min. Typ. Max. Units Notes & Conditions DYNAMIC CHARACTERISTICS Output Voltage during Load Current Transient Step Change in Output Current (0.1 A/µs) 350 mV 50% to 75% to 50% Iout max Settling Time 100 µs To within 1% Vout nom Turn-On Transient Turn-On Time (with 5 mF output capacitance) 15 25 ms Half load, Vout=90% nom. Start-Up Inhibit Time 200 ms -40 °C to +125 °C; Figure E Output Voltage Overshoot 0 % 5 mF load capacitance ISOLATION CHARACTERISTICS Isolation Voltage (dielectric strength) 2000 V See Absolute Maximum Ratings Isolation Resistance 30 MΩ Isolation Capacitance (input to output) 470 pF See Note 3 Semiconductor Junction Temperature 125 °C Package rated to 150 °C Board Temperature 125 °C UL rated max operating temp 130 °C Transformer Core Temperature 125 °C Maximum Baseplate Temperature, Tb 100 °C FEATURE CHARACTERISTICS Switching Frequency 175 200 225 kHz ON/OFF Control (Option P) Off-State Voltage -1 0.8 V On-State Voltage 2.4 18 V ON/OFF Control (Option N) On-State Voltage -1 0.8 V Off-State Voltage 2.4 18 V ON/OFF Control (Either Option) Application notes Figures A & B Pull-Up Voltage 5 V Pull-Up Resistance 124 kΩ Over-Temperature Shutdown OTP Trip Point 135 °C Average PCB Temperature Over-Temperature Shutdown Restart Hysteresis 10 °C RELIABILITY CHARACTERISTICS Calculated MTBF (Telcordia) TR-NWT-000332 4.8 106 Hrs. 80% load, 200LFM, 40 °C Ta Calculated MTBF (MIL-217) MIL-HDBK-217F 3.3 106 Hrs. 80% load, 200LFM, 40 °C Ta Field Demonstrated MTBF 106 Hrs. See our website for details Note 1: UL’s product certification tests were carried out using 20 A fast blow fuse. Fuse interruption characteristics have to be taken into account while Note 2: For applications requiring reduced output voltage ripple and noise, consult SynQor applications support (e-mail: support@synqor.com) Note 3: Isolation capacitance can be added external to the module. |
Similar Part No. - BQ57120QEX50 |
|
Similar Description - BQ57120QEX50 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |