2 / 9 page CINT1275 275W Single Output Industrial Series www.slpower.com CINT1275 REV 1.4 22-JAN-14 2 General Specifications (continued) Input Fuses F1, F2: 5A, 275Vac fuses provided on all models Overload Protection 120 to 150% of rating, Hiccup Mode Earth Leakage Current <750µA@264Vac, 60Hz, NC Short Circuit Protection Hiccup Mode, auto recovery. Efficiency 92% typical Overvoltage Protection OVP latch at 110 to 130% of output voltage Output Power 275W continuous, with 200 lfm airflow, 180W convection cooled – See chart for specific voltage model ratings. Switching Frequency PFC: Variable, 30kHz - 400kHz Main Converter: Variable 30-250kHz, 65- 70kHz at full load. Transient Response 500µS typical, return to 0.5% of nominal, 50% load step. ∆i/∆t: <0.2A/µS. Max Voltage Deviation = 3% Isolation Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 1500Vac Ripple and Noise 0.5%rms, 1% pk-pk, see chart. Operating Temperature -10°C to +70°C Start Up at -40°C, full load Output Voltage See chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C Voltage Adjustability +/-5% from nominal (except 56V) Storage Temperature -40°C to +85°C Minimum Load Not required Altitude Operating: -500 to 10,000 ft. Non-operating: -500 to 40,000 ft. Total Regulation +/- 3% combined line, load and initial setting. Relative Humidity 5% to 95%, non-condensing Vibration Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g2/Hz, 5.0grms overall, 3 axes, 1 hr/axis Shock Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total Dimensions W: 3.0” x L: 5.0” x H: 1.40” (from bottom of PC Board). Safety Standards EN/CSA/UL/IEC 60950-1, 2nd Edition Weight 325g MTBF 465,000 hours, 275W load, 110Vac input, 25°C ambient Auxiliary Signals Standby Output 5V @ 200 mA DC OK: Open collector logic signal goes and stays HIGH 100mS to 500mS after main output reaches regulation. AC Power Fail: Goes LOW with 5mS warning before loss of DC output after loss of AC power. Fan Output: 12V @ 1A Inhibit: Connect to inhibit pin (J201 pin 5) to output common to inhibit the DC output. Current Share: Forced Current Sharing provided for up to 5 units connected in parallel. Remote Sense: Compensates for up to 250mV drop in load lines. |
Similar Part No. - CINT1275A1514K01 |
|
Similar Description - CINT1275A1514K01 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |