Electronic Components Datasheet Search |
|
B1511A Datasheet(PDF) 3 Page - Agilent(Hewlett-Packard) |
|
B1511A Datasheet(HTML) 3 Page - Agilent(Hewlett-Packard) |
3 / 23 page 2 Basic Features • PC-based instrument with touch screen interface; optional USB keyboard and mouse available • EasyEXPERT software with over 200 categorized application tests supplied with the instrument • Performs current versus voltage (IV) measurements • Performs capacitance versus voltage (CV), capacitance versus time (Ct) and capacitance versus frequency (Cf) measurements • Performs quasi-static CV (QSCV) measurements • High voltage pulse forcing up to 40 V with ALWG and voltage monitor capabilities. • Performs fast IV measurement synchro- nized with the applied waveforms for accurate transient IV or time-domain measurements • Front-panel Classic Test measurement modes supported: single-channel sweep, multi-channel sweep, time sampling, list sweep, CV sweep and direct control (GPIB FLEX) • GUI-based control of the Agilent B2200A, and B2201A switching matrices • Modular mainframe with ten module slots and one 4.2 A ground unit • Multiple source/monitor unit (SMU) types available: medium power (MPSMU), high-power (HPSMU), and high-resolution (HRSMU) • Multi-frequency capacitance measure- ment unit (MFCMU) available • High-voltage semiconductor pulse generator unit (HV-SPGU) available • Waveform generator/fast measurement unit (WGFMU) available • High-resolution, analog-to-digital converter (ADC) available to all installed SMUs • High-speed ADC present on each installed SMU • SMU/AUX path switching supported on the atto-sense and switch unit (ASU) • SMU/MFCMU switching supported using SMU CMU unify unit (SCUU) and guard switch unit (GSWU) • MFCMU automatically identifies capacitance measurement accessories • WGFMU/SMU path switching supported on the remote-sense and switch unit (RSU) • GPIB port for instrument control • Self-test, self-calibration, diagnostics Specification conditions This document lists specifications and supplemental information for the B1500A and its associated modules. The specifica- tions are the standards against which the B1500A and its associated modules are tested. When the B1500A and any of its associated modules are shipped from the factory, they meet the specifications. The “supplemental” information and “typical” entries in the following specifications are not warranted, but provide useful informa- tion about the functions and performance of the instrument. B1500A specification Supported plug-in modules The B1500A supports ten slots for plug-in modules. Part number Description Slots occupied Range of operation Measure resolution B1510A High power source/monitor unit (HPSMU) 2 -200 V to 200 V, -1 A to 1 A 2 µV, 10 fA B1511A Medium power source/monitor unit (MPSMU) 1 -100 V to 100 V, -100 mA to 100 mA 0.5 µV, 10 fA B1517A High resolution source/monitor unit (HRSMU) 1 -100 V to 100 V, -100 mA to 100 mA 0.5 µV, 1 fA E5288A¹ Atto-sense and switch unit (ASU) — -100 V to 100 V, -100 mA to 100 mA 0.5 µV, 100 aA B1520A Multi frequency capacitance measurement unit (MFCMU) 1 1 kHz to 5 MHz 0.035 fFrms² B1525A High voltage semiconductor pulse generator unit (HV-SPGU) 1 ±40 V (80 Vp-p) 50 μV B1530A Waveform generator/fast measurement unit (WGFMU) 1 PG Mode: -3 V to 3 V, -5 V to 5 V Fast IV Mode: -3 V to 3 V, -5 V to 5 V, 0 V to 10 V, -10 V to 0 V 0.014 % of the range 3 1. This is connected with the B1517A high resolution SMU. 2. Dispersion of measurement values when connecting a DUT 10 pF to the measurement terminals under the measurement condition of frequency 1 MHz, signal level 250 mVac, and measurement time 1 PLC. The display resolution is 0.000001 fF at 1 fF order by 6 digits display. 3. Display resolution The measurement and output accuracy are specified at the rear panel connector terminals when referenced to the Zero Check terminal. The B1530A WGFMU measurement and output accuracy are specified at the output terminal of the RSU. Accuracy is specified under the following conditions: 1. Temperature: 23 °C ±5 °C 2. Humidity: 20 % to 60 % 3. After 40 minute warm-up followed by self-calibration 4. Ambient temperature change less than ±1 °C after self-calibration execution, not applicable for MFCMU and WGFMU 5. Measurement made within one hour after self-calibration execution, not applicable for MFCMU and WGFMU 6. Calibration period: 1 year 7. SMU integration time setting: 1 PLC (1 nA to 1A range, voltage range) 20 PLC (100 pA range) 50 PLC (1 pA to 10 pA range) Averaging of high-speed ADC: 128 samples per 1 PLC 8. SMU filter: ON (for SMUs) 9. SMU measurement terminal connection: Kelvin connection 10. WGFMU load capacitance: 25 pF or less Note: Agilent Technologies is responsible for removing, installing, and replacing the B1500A modules. Contact your nearest Agilent Technologies to install and calibrate the B1500A modules |
Similar Part No. - B1511A |
|
Similar Description - B1511A |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |