2 / 4 page MCWI03 SERIES DC/DC CONVERTER 3W, SIP-Package E-mail:sales@minmax.com.tw Tel:886-6-2923150 2015/07/31 REV:7 Page 2 of 4 ® Input Specifications Parameter Model Min. Typ. Max. Unit Input Surge Voltage (1 sec. max.) 12V Input Models -0.7 --- 25 VDC 24V Input Models -0.7 --- 50 48V Input Models -0.7 --- 100 Start-Up Threshold Voltage 12V Input Models 3 4 4.5 24V Input Models 4.5 6 9 48V Input Models 8.5 12 18 Under Voltage Shutdown 12V Input Models --- 3.5 4 24V Input Models --- --- 8 48V Input Models --- --- 16 Short Circuit Input Power All Models --- --- 2500 mW Input Filter Internal Capacitor Remote On/Off Control Parameter Conditions Min. Typ. Max. Unit Converter On Under 0.6 VDC or Open Circuit, drops down to 0VDC by 2mV/℃ Converter Off 2.7 --- 15 VDC Device Standby Input Current --- 1 2.5 mA Control Input Current ( on ) Vin = 0V --- --- 1 mA Control Input Current ( off ) Vin = 5.0V --- --- 1 mA Control Common Referenced to Negative Input Output Specifications Parameter Conditions Min. Typ. Max. Unit Output Voltage Setting Accuracy --- --- ±1.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads --- ±0.5 ±2.0 % Line Regulation Vin=Min. to Max. @Full Load --- ±0.3 ±0.5 % Load Regulation Io=25% to 100% --- ±0.5 ±1.0 % Ripple & Noise 0-20 MHz Bandwidth --- --- 75 mV P-P Transient Recovery Time 25% Load Step Change --- 300 500 μsec Transient Response Deviation --- ±3 ±5 % Temperature Coefficient --- --- ±0.02 %/℃ Over Load Protection Foldback 110 140 --- % Short Circuit Protection Continuous, Automatic Recovery General Specifications Parameter Conditions Min. Typ. Max. Unit I/O Isolation Voltage 60 Seconds 1600 --- --- VDC 1 Second 1920 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- MΩ I/O Isolation Capacitance 100KHz, 1V --- 200 --- pF Switching Frequency --- 350 --- KHz MTBF (calculated) MIL-HDBK-217F@25℃, Ground Benign 800,000 Hours Safety Approvals UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report) Environmental Specifications Parameter Conditions Min. Max. Unit Operating Ambient Temperature Range (See Power Derating Curve) Natural Convection -40 +85 ℃ Case Temperature --- 105 ℃ Storage Temperature Range -55 +125 ℃ Humidity (non condensing) --- 95 % rel. H Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- 260 ℃ |
Similar Part No. - MCWI03_16 |
|
Similar Description - MCWI03_16 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |