11 / 15 page NCL30060 www.onsemi.com 11 IRT(dis) which has 50 mA typical value. After the device is disabled, the integrated HV source maintains VCC above VCC(min). The IC is activated when the voltage of the RT pin is higher than the VRT(enable), which has typical value of 400 mV. And the RT pin output current is switched back to normal operation, and the RT voltage is regulated to VRT(REG),which has a typical value of 2 V. The timing resistor should be placed as close as possible to the RT and GND pins with short trace lengths. Care should be taken to keep switching nodes (high dv/dt) away from RT to reduce noise pickup. CURRENT SENSE, ZERO CURRENT AND OVERVOLTAGE DETECTION The NCL30060 uses a novel architecture combining the current sense, the zero current detector (ZCD), output overvoltage and shorted output detector functions in a single terminal. Figure 6 shows the circuit schematic of the current sense and ZCD detectors. Figure 6. Current Sense and ZCD Detectors Schematic Short Winding Comparator CS/ZCD Peak Current Comparator ZCD Comparator Disable DRV Reset UVLO Edge Detector ZCD Blanking Time Selector ILIM2, OVP GND R S Q Q UVLO Clamp DRV Counter Reset Count ACTIVE ILIM2 Re−start Edge Detector HV(high) DRV DRV Reset Dominant Latch toff1,2 Timer VILIM1 VILIM2 VZCD VCC VCC LEB tCS(LEB1) LEB tCS(LEB2) VCC CURRENT SENSE The Switch current is sensed across a sense resistor, Rsense, and the resulting voltage ramp is applied to the CS/ZCD pin. The current signal is blanked by a leading edge blanking (LEB) circuit. The blanking period eliminates the leading edge spike and high frequency noise during the switch turn−on event. The LEB period, tCS(LEB1), is typically 325 ns. The Current Limit Comparator disables the driver once the current sense signal exceeds the current sense reference, VILIM1, typically 0.25 V. The next switching cycle is initiated by the ZCD or watchdog timer. A severe overload fault like a secondary side winding short circuit causes the switch current to increase very rapidly during the on−time. The current sense signal significantly exceeds VILIM1. But, because the current sense signal is blanked by the LEB circuit during the switch turn on, the current could damage the system. The NCL30060 protects against this fault by adding an additional comparator, Short Circuit Comparator. The current sense signal is blanked with a shorter LEB duration, tCS(LEB2), typically 125 ns, before applying it to the Short Circuit Comparator. The voltage threshold of the comparator, VILIM2, typically 0.5 V, is set twice the level of VILIM1, to avoid interference with normal operation. Four consecutive faults detected by the Short Circuit Comparator causes the controller to enter a fault mode. The NCL30060B will auto−recover from the fault state if the short is removed. The count to 4 provides noise immunity during surge testing. The counter is reset each time a DRV pulse occurs without activating the Short Circuit Comparator. The watchdog timer duration (toff2) is increased to 1.25 ms independent of the PFC ZCD state. |
Similar Part No. - NCL30060_16 |
|
Similar Description - NCL30060_16 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |