Electronic Components Datasheet Search |
|
REM6-2412DW Datasheet(PDF) 4 Page - Recom International Power |
|
REM6-2412DW Datasheet(HTML) 4 Page - Recom International Power |
4 / 6 page DC/DC Converter Specifications (measured at TA= 25°C, nominal input voltage, full load and after warm-up) Isolation Voltage I/P to O/P working voltage 5kVAC / 1 minute 250VAC / continuous Means of Protection 2MOPP Leakage Current 240VAC, 60Hz 2µA Medical Device Classification Type CF applied device (design to meet) Internal Clearance Creepage I/P to O/P I/P to O/P 8mm 8mm External Clearance Creepage I/P to O/P, Single Output I/P to O/P, Dual Output I/P to O/P, Single Output I/P to O/P, Dual Output >19.72mm >14.64mm >19.72mm >14.64mm Isolation Capacitance 12pF typ. / 17pF max. Insulation Grade Reinforced Insulation MED-4 REV.: 05/2016 www.recom-power.com ENVIRONMENTAL Parameter Condition Value Relative Humidity 5% to 95% RH Temperature Coefficient ±0.02% / °C Thermal Impedance natural convection (20LFM) 18°C / W max. Case Temperature Range max. Ambient Temperature Range -40°C to +105°C see calculation example MTBF (+25°C) according to MIL-HDBK-217F, full load 4718 x 103 hours REM6 Series Notes: Note5: This Power module is not internally fused. A input line fuse must be always used. Recomended Fuse: 2:1 Input Voltage Fuse (slow blow) 5V T2.5A 12V T1.25A 24V T0.63A 48V T0.315A 4:1 Input Voltage Fuse (slow blow) 24V T1.25A 48V T0.63A SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard CB Medical Safety E314885-A6 IEC-60601-1 1409015 Medical Report + ISO14971 Risk Assessment ANSI/AAMI E314885-A6 ES60601-1 CAN/CSA Medical E314885-A6 C22.2 No. 60601-1:08 Certificate Type (Others) Conditions Standard / Criterion EMI Standard (7) Conducted EN55011 (EN-55022), Class A, B Radiated EN55011 (EN-55022), Class A, B Conducted and Radiated FCC18 ESD Air ±8kV; Contact ±6kV EN61000-4-2, Criteria A Radiated Immunity 10V/m EN61000-4-3, Criteria A Fast Transient (6) ±2kV EN61000-4-4, Criteria A Surge (6) ±2kV EN61000-4-5, Criteria A Conducted Immunity 20Vr.m.s EN61000-4-6, Criteria A continued on next page |
Similar Part No. - REM6-2412DW |
|
Similar Description - REM6-2412DW |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |