Specification
100150 Watts
110 VDC Input for Rail Applications
Up to 92% Efficiency
Quarter and Half Brick Packages
40 °C to +100 °C Operating Temperature
Baseplatecooled
Remote On/Off & Remote Sense
3 Year Warranty
RDQ Series
Input
Input Voltage Range
• 66-160 VDC
Input Current
• See table
Idle Current
• 50 mA
Input Filter
• Pi network (see note 3)
Undervoltage Lockout
• Turn on 62.0 V, turn off 56.0 V
Input Surge
• 180 VDC for 100 ms
Output
Output Voltage Trim
• ±10%, see application notes
Initial Set Accuracy
• ±1.5% max
Line Regulation
• ±0.2% max measured from high line
to low line
Load Regulation
• ±0.2% max measured from 0-100% load
Start Up Time
• 60 ms typical
Transient Response
• 5% max deviation, recovery to within
1% in 200 µs, 25% step load change
Ripple & Noise
• 5 V models: 100 mV pk-pk
12 V models: 150 mV max pk-pk
24 V models: 240 mV max pk-pk
20 MHz bandwidth (see note 1)
Overvoltage Protection
• 115-140%
Short Circuit Protection
• Continuous
Current Limit
• 110-180% nominal output
Thermal Shutdown
• Case temperature >105 °C typical
Temperature
• ±0.03%/°C
Coefficient
Remote On/Off
• Referenced to -Vin,
Module on = open circuit,
Module off ≤0.8 VDC
Remote Sense
• Compensates up to 10% of Vout nominal,
total of output trim and remote sense
General
Efficiency
• See tables
Isolation Voltage
• 2250 VDC Input to Output
2250 VDC Input to Case
1500 VDC Output to Case
Isolation Resistance
• 107
Isolation Capacitance
• 1000 pF typical
Switching Frequency
• 200 kHz typical
Power Density
• RDQ100: 60 W/in3, RDQ150: 54 W/in3
MTBF
• 380 kHrs typical to MIL-HDBK-217F
at 25 °C, GB
xppower.com
Environmental
Operating Base Plate
• -40 °C to +100 °C, see derating curve
Temperature
Storage Temperature
• -55 °C to +105 °C
Operating Humidity
• Up to 95% non-condensing
Cooling
• Baseplate-cooled, see derating curve
Cooling Test
• EN60068-2-1, -40 °C for 2 hours
Dry Heat
• EN60068-2-2, 70 °C for 6 hours
Damp Heat
• EN60068-2-30, 25 °C to 55 °C, 90-100%
humidity, 2 cycles of 24 hours
Vibration
• EN61373, 2 Hz to 150 Hz, 5.72m/s2 on X
axis, 2.55m/s2 on Y axis, 3.96m/s2 on Z axis
Shock
• EN61373, 50m/s2 half sine 30ms, 3
positive and 3 negative on X axis,
30m/s2 half sine 30ms, 3 positive and 3
negative on Y and Z axes,
Supply Variation
• EN50155, 0.7 to 1.4 Vn
Supply Interruption
• EN50155, 100% for 10 ms
Supply Change-Over
• EN50155, 0.6 Vn for 100 ms
Insulation Test
• EN50155, 500 VDC
Voltage Withstand
• EN50155, 2250 VDC
Supply Over-Voltage
• EN50155, 1.4 Vn for 0.1 s
EMC & Safety
General
• Complies with EN50121-3-2, Railway
Applications - Electromagnetic
Compatibility for Rolling Stock Apparatus
Emissions
• EN55011, 99 dBµV (0.15-0.5 MHz). 93
dBµV (0.5-30 MHz) conducted,
class A radiated, EN55022 Level B
conducted with external filter, see
Application Notes.
ESD Immunity
• EN61000-4-2 Air ±8kV, contact ±6kV,
indirect ±6kV, Perf Criteria A
Radiated Immunity
• EN61000-4-3 80-1000 MHz at 20 V/m,
1400-2100 MHz at 10V/m, 2100-2500
MHz at 5 V/m, Perf Criteria A
EFT/Burst
• EN61000-4-4 level 3, Perf Criteria A
Surge
• EN61000-4-5 level 2, Perf Criteria A*
Conducted Immunity
• EN61000-4-6 10 Vrms, Perf Criteria A
Safety Approval
• UL60950-1 (basic insulation)
Notes
* External TVS is required on the input. See Application Notes.


Similar Description - RDQ100110S12

ManufacturerPart #DatasheetDescription
logo
MicroPower Direct, LLC
MDCFM-40U MPD-MDCFM-40U Datasheet
842Kb / 4P
   40 to 110 VDC Input
logo
Power-One
MAP80 POWER-ONE-MAP80 Datasheet
234Kb / 4P
   Wide Range Input for 110/220 VAC Applications
MAP40 POWER-ONE-MAP40 Datasheet
127Kb / 3P
   Wide Range Input for 110/220 VAC Applications
logo
WAGO Kontakttechnik Gmb...
753-427 WAGO-753-427 Datasheet
532Kb / 12P
   2-channel digital input; 110 VDC
logo
Bel Fuse Inc.
0RQB-30Y05S BEL-0RQB-30Y05S Datasheet
960Kb / 19P
   24 / 48 / 72 / 96 / 110 VDC Input
0RQB-15Y05X BEL-0RQB-15Y05X Datasheet
558Kb / 16P
   24/48/72/96/110 VDC Input
0RQB-30Y05L BEL-0RQB-30Y05L Datasheet
772Kb / 17P
   24 / 48 / 72 / 96 / 110 VDC Input
logo
WAGO Kontakttechnik Gmb...
286-307-004-000 WAGO-286-307-004-000 Datasheet
317Kb / 6P
   Relay module; Nominal input voltage: 110 VDC
logo
Bel Fuse Inc.
0RQB-C5W24X BEL-0RQB-C5W24X Datasheet
879Kb / 21P
   50 / 110 / 160 VDC Input Input Under Voltage Lockout
logo
Texas Instruments
OPA863 TI-OPA863_V02 Datasheet
2Mb / 42P
[Old version datasheet]   OPAx863 Low-Power, 110-MHz, Rail-to-Rail Input and Output Amplifier
NOVEMBER 2021
More results


Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com