2 / 2 page Notes: A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load. B. To maintain specified regulation on multi-output models, output #1 load power must be at least 1/5th of, and not greater than 5 times output #2 load power. C. Add “G” suffix to model number for RoHS compliant model. Commercial Model Medical Model Output No. Output Current Minimum Load (B) OVP Setpoint Noise P-P Total Regulation (A) GLC50A GLM50A 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +12 V 2.5 A 120 mV +10%,-5% 3 -12 V 0.2 A 120 mV 3% GLC50B GLM50B 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +15 V 2.5 A 150 mV +10%,-5% 3 -15 V 0.2 A 150 mV 3% GLC50D GLM50 D 1 +5.05 V 4 A 0.8 A 6.2 ± 0.6 V 50 mV 2% 2 +24 V 1.5 A 240 mV +10%,-5% 3 -12 V 0.2 A 120 mV 3% GLC50G GLM50G 1 +3.3 V 4 A 0.8 A 4.2 ± 0.6 V 33 mV 2% 2 +12 V 2.5 A 120 mV +10%-5% 3 -12 V 0.2 A 120 mV 3% GLC50-3.3 GLM50-3.3 1 3.3 V 8 A 0.2 4.2 ± 0.6 V 66 mV 2% GLC50-5 GLM50-5 1 5.1 V 8 A 0.4 6.2 ± 0.6 V 75 mV 2% GLC50-12 GLM50-12 1 12 V 4.2 A 0.2 14 ± 1.1 V 120 mV 2% GLC50-15 GLM50-15 1 15 V 3.3 A 0.16 18.5 ± 1.5 V 150 mV 2% GLC50-24 GLM50-24 1 24 V 2.1 A 0.1 28 ± 2.5 V 240 mV 2% GLC50-28 GLM50-28 1 28 V 1.8 A 0.09 34.5 ± 2.8 V 280 mV 2% GLC50-48 GLM50-48 1 48 V 1.1 A 0.05 54 ± 3.0 V 480 mV 2% SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. Rev. 1/07. Data Sheet © 2007 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Condor accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. GLC50 MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) 0 TO 50°C -40 to +85°C Humidity (A) 0 to 95% RH 0 to 95% RH Shock (B) 20 g pk 40 g pk Altitude -500 to 10,000 ft -500 to 40,000 ft Vibration (C) 1.5 g rms’ 0.003 g 2 /Hz 5 g rms’ 0.026 g 2 /Hz A. Units should be allowed to warm up/operate under non-condensing condi- tions before application of power. derate output current and total output power by 2.5% per °C above 50°C. B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. |
Similar Part No. - GLM50A |
|
Similar Description - GLM50A |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |