Electronic Components Datasheet Search |
|
MAX820RCSE Datasheet(PDF) 7 Page - Maxim Integrated Products |
|
MAX820RCSE Datasheet(HTML) 7 Page - Maxim Integrated Products |
7 / 16 page Microprocessor and Non-Volatile Memory Supervisory Circuits _______________________________________________________________________________________ 7 ______________________________________________________________Pin Description PIN NAME FUNCTION 1 RESET 2 RESET Reset is the inverse of RESET. 3VCC Input Supply Voltage 4 RESET IN/INT 5 LLIN/REF OUT 6 OVO 7 OVI 8 SWT 9 MR 10 LOW LINE 11 WDI 12 GND Ground 13 CE OUT Active-Low Reset Output goes low whenever VCC falls below the reset threshold in internal thresh- old programming mode, or RESET IN falls below 1.30V in external threshold programming mode. RESET remains low for 200ms typ after the threshold is exceeded on power-up. Reset-Input/Internal-Mode Select. Connect this input to GND to select internal threshold mode. Select external programming mode by pulling this input 600mV or higher through an external volt- age divider. Low-Line Input/Reference Output connects directly to the low-line comparator in external program- ming mode (RESET IN/INT ≥ 600mV). Connects directly to the internal 1.30V reference in internal threshold mode (RESET IN/INT ≤60mV). Overvoltage Comparator Output goes low when OVI is greater than 1.30V. This is an uncommitted comparator and has no effect on any other internal circuitry. Inverting Input to the Overvoltage Comparator. When OVI is greater than 1.30V, OVO goes low. Connect OVI to GND or VCC when not used. Set Watchdog-Timeout Input. Connect this input to VCC to select the default 1.6sec watchdog timeout period. Connect a capacitor between this input and GND to select another watchdog- timeout period. Watchdog timeout period = k x (capacitor value in nF)mV, where k = 27 for VCC = 5V and k = 16.2 for VCC = 3V. If the watchdog function is unused, connect SWT to VCC. 16 WDPO 15 WDO 14 CE IN Manual-Reset Input. This input can be tied to an external momentary pushbutton switch, or to a logic gate output. Internally pulled up to VCC. Low-Line Output. LOW LINE goes low 120mV above the reset threshold in internal threshold mode, or when LLIN/REFOUT goes below 1.30V in external programming mode. Watchdog Input. If WDI remains either high or low for longer than the watchdog timeout period, WDPO pulses low and WDO goes low. WDO remains low until the next transition at WDI. Connect to GND or VCC if unused. Chip-Enable Output. CE OUT goes low only when CE IN is low and reset is not asserted. If CE IN is low when reset is asserted, CE OUT will stay low for 15µs or until CE IN goes high, whichever occurs first. Chip-Enable Input—the input to the chip-enable transmission gate. Connect to GND or VCC if not used. Watchdog Output. WDO goes low if WDI remains either high or low longer than the watchdog time- out period. WDO returns high on the next transition at WDI. Watchdog-Pulse Output. Upon the absence of a transition at WDI, WDPO will pulse low for a mini- mum of 500µs. WDPO precedes WDO by typically 70ns. |
Similar Part No. - MAX820RCSE |
|
Similar Description - MAX820RCSE |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |