Electronic Components Datasheet Search |
|
ZSSC3122 Datasheet(PDF) 11 Page - List of Unclassifed Manufacturers |
|
ZSSC3122 Datasheet(HTML) 11 Page - List of Unclassifed Manufacturers |
11 / 29 page ZSC31210/ZSSC3122/ZSSC3123 cLite™ SSC Modular Evaluation Kit Description Evaluation Kit June 30, 2011 © 2011 Zentrum Mikroelektronik Dresden AG — Rev. 1.1 All rights reserved. The material contained herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. The information furnished in this publication is subject to changes without notice. 11 of 28 4.2.1 Special Feature “Set I 2C Speed” This feature sets the I 2C speed to a different frequency (default value: 100kHz). 4.2.2 Special Feature “Find I 2C Address” This feature finds the I 2C address of the cLite™. This can be used if the address was accidentally changed and communication is locked. 4.2.3 Special Feature “Power up all DUTs” This feature is only used for the Mass Calibration Board. 4.3 “Open Port” Button The cLite™ SSC Evaluation Software provides a drop-down menu for selection of all available COM ports on the PC. Select the correct COM port from the drop-down menu (see section 2). To set up communication with the SSC CB, click on “Open Port” (see Figure 4.1), which then toggles to “Close Port.” If the port is opened successfully, “Opened port COMx” will appear in the status window. 4.4 Display Selection During normal operation, it is possible to display the sensor and temperature data output in one of three different formats. The “Display” section at the top left allows the user to select decimal, hexadecimal, or percent and degrees Celsius. The selected format is displayed in the sensor and temperature display boxes below the “Display” section (see section 4.6). 4.5 “Master I2C Addr” Section Use the “I2C Addr” field at the top to enter the address that the SSC CB uses to communicate with the cLite™ installed in the socket on the SSC Evaluation Board. Then click “Set Address.” Valid settings are 00HEX to 7FHEX. The default is 28HEX. See important notes in section 4.12.2 regarding settings when the communication address is locked. 4.6 Sensor and Temperature Display The software displays two large readout windows for sensor and temperature values at the top left. The upper display window is the cLite™ temperature reading in decimal/hexadecimal/ oC. The window below the temperature is the sensor reading in decimal/hexadecimal/%. To adjust the rate at which data is read from the IC, use the rate adjustment (see section 4.8). If the cLite™ has not been temperature calibrated, the displayed temperature is invalid. The different colors of the display field indicate the cLite™ mode: Color Green Blue Red Yellow IC Mode/State Valid value in Normal Operating Mode (NOM) Valid in Command Mode (CM) Diagnostic Stale Data (NOM) ‡ ‡ For more details, refer to the appropriate datasheet (ZSC31210_cLite_Datasheet.pdf, ZSSC3122_cLite_Datasheet.pdf, or ZSSC3123_cLite_Datasheet.pdf). |
Similar Part No. - ZSSC3122 |
|
Similar Description - ZSSC3122 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |