Electronic Components Datasheet Search |
|
MAX6726KAD-T Datasheet(PDF) 9 Page - Maxim Integrated Products |
|
MAX6726KAD-T Datasheet(HTML) 9 Page - Maxim Integrated Products |
9 / 19 page Detailed Description Supply Voltages The MAX6715–MAX6729 microprocessor (µP) supervi- sory circuits maintain system integrity by alerting the µP to fault conditions. These ICs are optimized for systems that monitor two or three supply voltages. The output- reset state is guaranteed to remain valid while either VCC1 or VCC2 is above 0.8V. Threshold Levels Input voltage threshold level combinations are indicat- ed by a two-letter code in the Reset Voltage Threshold Suffix Guide (Table 1). Contact factory for availability of other voltage threshold combinations. Reset Outputs The MAX6715–MAX6729 provides an active-low reset output (RST) and the MAX6725/MAX6726 provides both an active-high (RST) and an active-low reset out- put (RST). RST, RST, RST1, and RST2 are asserted when the voltage at either VCC1 or VCC2 falls below the voltage threshold level, RSTIN drops below threshold, or MR is pulled low. Once reset is asserted it stays low for the reset timeout period (see Table 2). If VCC1, VCC2, or RSTIN goes below the reset threshold before the reset timeout period is completed, the internal timer Dual/Triple Ultra-Low-Voltage SOT23 µP Supervisory Circuits _______________________________________________________________________________________ 9 Pin Description (continued) PIN MAX6715/ MAX6716 MAX6717/ MAX6718 MAX6719/ MAX6720 MAX6721/ MAX6722 MAX6723/ MAX6724 MAX6725/ MAX6726 MAX6727 MAX6728/ MAX6729 NAME FUNCTION —— ——— —— 4 PFO Active-Low Power-Fail Monitor Output, Open- Drain or Push-Pull. PFO is asserted low when PFI is less than 0.626V. PFO deasserts without a reset timeout period. Open- drain outputs require an external pullup resistor. Push-pull outputs are referenced to VCC1. —— ——— 4 — — RST Active-High Reset Output, Open-Drain or Push-Pull. RST changes from low to high when VCC1 or VCC2 drops below selected reset thresholds, RSTIN is below threshold, MR is pulled low, or the watchdog triggers a reset. RST remains HIGH for the reset timeout period after VCC1/ VCC 2/RSTIN exceed the device reset thresholds, MR goes low to high, or the watchdog triggers a reset. Open-drain outputs require an external pullup resistor. Push-pull outputs are referenced to VCC1. |
Similar Part No. - MAX6726KAD-T |
|
Similar Description - MAX6726KAD-T |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |