4 / 12 page 4 www.irf.com AFL28XXS Series Dynamic Characteristics -55°C < T CASE < +125°C, VIN=28V unless otherwise specified. Notes to Specifications: 1. Parameters not 100% tested but are guaranteed to the limits specified in the table. 2. Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1.0% of VOUT at 50% load. 3. Line transient transition time ≥ 100µs. 4. Turn-on delay is measured with an input voltage rise time of between 100V and 500V per millisecond. 5. Current limit point is that condition of excess load causing output voltage to drop to 90% of nominal. 6. Parameter verified as part of another test. 7. All electrical tests are performed with the remote sense leads connected to the output leads at the load. 8. Load transient transition time ≥ 10µs. 9. Enable inputs internally pulled high. Nominal open circuit voltage ≈ 4.0VDC. Parameter Group A Subgroups Test Conditions Min Nom Max Unit LOAD TRANSIENT RESPONSE AFL2805S Amplitude Recovery Amplitude Recovery AFL2807S Amplitude Recovery Amplitude Recovery AFL2808S Amplitude Recovery Amplitude Recovery AFL2809S Amplitude Recovery Amplitude Recovery AFL2812S Amplitude Recovery Amplitude Recovery AFL2815S Amplitude Recovery Amplitude Recovery AFL2828S Amplitude Recovery Amplitude Recovery 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 4, 5, 6 Note 2, 8 Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% Load Step 50% ⇔ 100% Load Step 10% ⇔ 50% -450 -450 -500 -500 -500 -500 -600 -600 -750 -750 -750 -750 -1200 -1200 450 200 450 400 500 200 500 400 500 200 500 400 600 200 600 400 750 200 750 400 750 200 750 400 1200 200 1200 400 mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs mV µs LINE TRANSIENT RESPONSE Amplitude Recovery Note 1, 2, 3 VIN Step = 16 ⇔ 40 Volts -500 500 500 mV µs TURN-ON CHARACTERISTICS Overshoot Delay 4, 5, 6 4, 5, 6 VIN = 16, 28, 40 Volts. Note 4 Enable 1, 2 on. (Pins 4, 12 high or open) 0 4.0 250 10 mV ms LOAD FAULT RECOVERY Same as Turn On Characteristics. LINE REJECTION MIL-STD-461D, CS101, 30Hz to 50KHz Note 1 40 50 dB |
Similar Part No. - AFL27009SXHB |
|
Similar Description - AFL27009SXHB |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |