Back Button PHYAD3 Datasheet HTML 4Page - Texas Instruments PHYAD3 Datasheet HTML 5Page - Texas Instruments PHYAD3 Datasheet HTML 6Page - Texas Instruments PHYAD3 Datasheet HTML 7Page - Texas Instruments PHYAD3 Datasheet HTML 8Page - Texas Instruments PHYAD3 Datasheet HTML 9Page - Texas Instruments PHYAD3 Datasheet HTML 10Page - Texas Instruments PHYAD3 Datasheet HTML 11Page - Texas Instruments PHYAD3 Datasheet HTML 12Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 135 page
background image
DP83630
SNLS335B – OCTOBER 2010 – REVISED APRIL 2013
www.ti.com
2.3.2
PACKET TIMESTAMPS
2.3.2.1
IEEE 1588 Transmit Packet Parser and Timestamp
The IEEE 1588 transmit parser monitors transmit packet data to detect IEEE 1588 Version 1 and Version
2 Event messages. The transmit parser can detect PTP Event messages transported directly in Layer2
Ethernet packets as well as in UDP/IPv4 and UDP/IPv6 packets. Upon detection of a PTP Event
Message, the device will capture the transmit timestamp and provide it to software.
Since software knows the order of packet transmission, only the timestamp is recorded (there is no need
to record sequence number or other information). The device can buffer four timestamps.
If enabled, an interrupt may be generated upon a Transmit Timestamp Ready.
2.3.2.1.1 One-Step Operation
In some cases, the transmitter can be set to operate in a One-Step mode. For Sync Messages, a One-
Step device can automatically insert timestamp information in the outgoing packet. This eliminates the
need for software to read the timestamp and send a follow up message.
2.3.2.2
IEEE 1588 Receive Packet Parser and Timestamp
The IEEE 1588 receive parser monitors receive packet data to detect IEEE 1588 Version 1 and Version 2
Event messages. The receive parser can detect PTP Event messages transported directly in Ethernet
packets as well as in UDP/IPv4 and UDP/IPv6 packets. Upon detection of a PTP Event message, the
device will capture the receive timestamp and provide the timestamp value to software. In addition to the
timestamp, the device will record the 16-bit SequenceId, the 4-bit messageType field, and generate a 12-
bit hash value for octets 20-29 of the PTP event message. The device can buffer four timestamps.
An interrupt will be generated, if enabled, upon a Receive Timestamp Ready.
2.3.2.2.1 Receive Timestamp Insertion
The DP83630 can deliver the timestamp to software by inserting the timestamp in the received packet.
This allows for a simple method to deliver the packet to software without having to match the timestamp to
the correct packet. This also eliminates the need to read the receive timestamp through the Serial
Management Interface.
2.3.2.3
NTP Packet Timestamp
The DP83630 may be programmed to timestamp NTP packets instead of PTP packets. This operation is
enabled by setting the NTP_TS_EN control in the PTP_TXCFG0 register. When configured for NTP
timestamps, the DP83630 will timestamp packets with the NTP UDP port number rather than the PTP port
number (note that the device cannot be configured to timestamp both PTP and NTP packets). One-Step
operation is not supported for NTP timestamps, so transmit timestamps cannot be inserted directly into
outgoing NTP packets. Timestamp insertion is available for receive timestamps but must use a single,
fixed location.
2.3.3
EVENT TRIGGERING AND TIMESTAMPING
2.3.3.1
IEEE 1588 Event Triggering
The DP83630 is capable of being programmed to generate a trigger signal on an output pin based on the
IEEE 1588 time value. Each trigger can be programmed to generate a one-time rising or falling edge, a
single pulse of programmable width, or a periodic signal.
For each trigger, the microcontroller specifies the desired GPIO and time that the activity is to occur. The
trigger is generated when the internal IEEE 1588 clock matches the desired activation time.
8
Device Information
Copyright © 2010–2013, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: DP83630


Similar Part No. - PHYAD3

ManufacturerPart #DatasheetDescription
logo
Maxim Integrated Produc...
PHY1076 MAXIM-PHY1076 Datasheet
930Kb / 49P
   125Mbps to 2.7Gbps Laser Driver/ Post Amp with Digital Diagnostics
19-5684; Rev 9/12
PHY1076-01 MAXIM-PHY1076-01 Datasheet
930Kb / 49P
   125Mbps to 2.7Gbps Laser Driver/ Post Amp with Digital Diagnostics
19-5684; Rev 9/12
PHY1076-01QD-RR MAXIM-PHY1076-01QD-RR Datasheet
930Kb / 49P
   125Mbps to 2.7Gbps Laser Driver/ Post Amp with Digital Diagnostics
19-5684; Rev 9/12
PHY1076-01QS-RR MAXIM-PHY1076-01QS-RR Datasheet
930Kb / 49P
   125Mbps to 2.7Gbps Laser Driver/ Post Amp with Digital Diagnostics
19-5684; Rev 9/12
PHY1090 MAXIM-PHY1090 Datasheet
730Kb / 10P
   0B10GbE Linear Transimpedance Amplifier
19-5686 ; Rev 1/11
More results

Similar Description - PHYAD3

ManufacturerPart #DatasheetDescription
logo
Texas Instruments
DP83630 TI1-DP83630 Datasheet
1Mb / 128P
[Old version datasheet]   DP83630 Precision PHYTER - IEEE짰 1588 Precision Time Protocol Transceiver
logo
National Semiconductor ...
DP83640 NSC-DP83640 Datasheet
2Mb / 114P
   Precision PHYTER - IEEE 1588 Precision Time Protocol Transceiver
logo
Texas Instruments
DP83640TVV TI1-DP83640TVV Datasheet
1Mb / 136P
[Old version datasheet]   DP83640 Precision PHYTER - IEEE 1588 Precision Time Protocol Transceiver
DP83640TVVX TI1-DP83640TVVX Datasheet
1Mb / 137P
[Old version datasheet]   DP83640 Precision PHYTER - IEEE 1588 Precision Time Protocol Transceiver
DP83640 TI1-DP83640_14 Datasheet
1Mb / 129P
[Old version datasheet]   Precision PHYTER - IEEE짰 1588 Precision Time Protocol Transceiver
logo
National Semiconductor ...
DP83640 NSC-DP83640_08 Datasheet
2Mb / 124P
   Precision PHYTER - IEEE짰 1588 Precision Time Protocol Transceiver
logo
Micrel Semiconductor
KSZ8463ML MICREL-KSZ8463ML Datasheet
3Mb / 259P
   IEEE 1588 Precision Time Protocol-Enabled, Three-Port, 10/100-Managed Switch with MII or RMII
KSZ8463RL MICREL-KSZ8463RL Datasheet
3Mb / 259P
   IEEE 1588 Precision Time Protocol- Enabled, Three-Port, 10/100-Managed Switch with MII or RMII
KSZ8462HL MICREL-KSZ8462HL Datasheet
3Mb / 279P
   IEEE 1588 Precision Time Protocol-Enabled Two-Port 10/100Mb/s Ethernet Switch with 8 or 16 Bit Host Interface
logo
Renesas Technology Corp
8A34012 RENESAS-8A34012 Datasheet
2Mb / 104P
   Port Synchronizer for IEEE 1588 Frequency and Time/Phase
November 30, 2021
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com