7 / 30 page www.ti.com Weigh Scale Mode Obtaining a calibration weight: Before the ADS1232REF can display the mass of an object, it must measure the output of the load cell for a previously known mass. The known mass can be adjusted. At power-up, the ADS1232REF expects a 5kg mass. If this mass is not available, or if the load cell range is not compatible with this mass, the calibration mass can be changed in the following manner: 1. Determine the mass of the calibration weight. The most accurate way to determine the mass is to weigh the calibration object on an accurately calibrated scale. If the weight is precalibrated, its given mass can be used, although this approach is not generally as accurate. (Note that the accuracy of the ADS1232REF as a scale directly depends on the accuracy to which the calibration weight can be measured.) 2. Switch the mode switch to SCALE mode. 3. Press the PARM buttons simultaneously. The ADS1232REF enters configuration mode. 4. Use the ENT and SEL buttons to select the screen which shows UNIT=. This screen allows you to select the units used for the calibration mass. If the units shown are not correct, adjust them using the PARM buttons. 5. Use the VALUE buttons to select the screen that shows CW= followed by the calibration mass. On this screen, you can adjust each digit of the calibration mass separately. Select the digit using the VALUE buttons. The currently-selected digit flashes, and can be adjusted using the PARM buttons. 6. Adjust the calibration mass to match the mass of the calibration weight. 7. Press the PARM buttons to exit the configuration mode. Preparing Scale mode: Do the following steps to set up the scale mode: 1. Connect the load cell. 2. If the input shorting jumpers J8 and J7 are connected, disconnect them (see Figure 1). 3. Obtain a weight of known mass. 4. If the mass of the weight is not equal to the configured calibration mass, adjust the calibration mass as described above. 5. Move the mode switch to SCALE position. If calibration has not been performed, the display reads NO CAL . 6. Press the CAL button, and follow the calibration procedure given in Section 2.3. If the calibration is performed properly, and the load cell is connected correctly, the ADS1232REF will measure the mass of an object placed on the load cell (provided that the mass of the object is within the device range). Weigh scale mode is described in detail in Section 2. 2 Weigh Scale Mode In weigh scale mode, the ADS1232REF displays mass.(1) Mass is displayed in either SI or avoirdupois units based on the voltage received from a load cell. The ADS1232REF operates in Scale mode when the mode switch is set to the Scale position. To accurately calculate mass, the ADS1232REF must have calibration information for the load cell. When scale mode is first entered, the ADS1232REF displays NO CAL, because the ADS1232REF has no calibration data when it is powered on. By default, mass is calculated from the average of four successive readings from the ADC. The number of points for averaging can be adjusted, and averaging can be turned off. (1) Load cells do not measure mass directly; they output a voltage proportional to the weight of an object. The mass of an object can be accurately inferred from this voltage as long as a calibration is accurately performed, the downward force of gravity remains constant (as it does if the load cell is not moved to a different altitude), and the tilt of the load cell does not change; if either of the latter conditions change, a new calibration must be performed. 7 SBAU120B – November 2005 – Revised July 2011 ADS1232REF User 's Guide Submit Documentation Feedback Copyright © 2005–2011, Texas Instruments Incorporated |
Similar Part No. - ERJ-8GEYJ200V |
|
Similar Description - ERJ-8GEYJ200V |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |