Electronic Components Datasheet Search |
|
TG315 Datasheet(PDF) 4 Page - List of Unclassifed Manufacturers |
|
TG315 Datasheet(HTML) 4 Page - List of Unclassifed Manufacturers |
4 / 4 page Technical Specifications Designed and built in Europe by: Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. Thurlby Thandar Instruments Ltd. Glebe Road, Huntingdon. Cambs. PE29 7DR United Kingdom (UK) Tel: +44 (0)1480 412451 Fax: +44 (0)1480 450409 Email: sales@tti-test.com Web: www.tti-test.com THURLBY THANDAR INSTRUMENTS TG300 Series 3MHz function and sweep/function generators simultaneous display of frequency & amplitude FREQUENCY Frequency Range: 0.03Hz to 3MHz in 7 overlapping decade ranges with fine adjustment by a vernier. Vernier Range: 1000:1 on each range. OPERATING MODES Specifications apply for the top decade of each frequency range and maximum out- put into 50 termination. SINE Distortion: <0.5% on 300, 3k and 30k ranges; <1% on 3, 30 and 300k ranges; all harmonics >25dB below fundamental on 3M range. Amplitude Flatness: ±0.2dB to 200kHz; ±2dB to 3MHz. TRIANGLE Linearity: Better than 99% to 200kHz SQUARE WAVE Rise/Fall Times: <100ns Mark - Space Ratio: 1:1 ± 1% to 100kHz DC Range: ±10V unterminated SYMMETRY Symmetry Range: Variable typically 1:9 to 9:1 (on top decade of each range), frequency divided by 10. METER FUNCTIONS (generator mode) Frequency: Auto-ranging reciprocal measurement giving 4 digit resolution for frequencies down to 1Hz; maximum resolution is 0.001Hz. Accuracy ±1 digit for 0.2Hz to 3MHz. Below 0.2Hz accuracy is ±1% of range full scale (symmetry off). Amplitude: Display shows peak-to-peak amplitude or rms value. Display corrected for attenuator set- ting. 3-digit resolution, accuracy typically 5% of range. Clipping indicator on display. DC Offset: 3-digit resolution; accuracy typically ±2% of setting ±1 digit. Display corrected for attenu- ator setting. Clipping indicator on display. OUTPUTS MAIN - 50 Ohm Amplitide 2mV to 20V peak-peak open circuit (1mV to 10V peak-peak into 50 Ω) in four switch- selectable ranges with 20dB vernier control within each range Attenuator Ranges: 0dB, -20dB, -40dB, -60dB DC Offset Range: ±10V from 50 Ω. DC offset plus signal peak limited to ±10V (±5V into 50 Ω). DC offset plus waveform attenuated proportionally by the attenuator. MAIN - 600 Ohm Alternative output socket offering the same facilities as the 50 Ω socket. AUX OUT 0 to 5V TTL/CMOS logic levels capable of driving 2 standard TTL loads. Frequency, symmetry and phase as main outputs SWEEP OUT 3V ramp from 600 Ω (TG330 only) EXTERNAL COUNTER (TG320 and TG330 only) Frequency Ranges: 5Hz to 25MHz and 20MHz to 120MHz, fully autoranging to maximum resolution Input Sensitivity: 50mV rms (sinewave) Input Impedance: 1M Ω/25pF Measurement Time: Selectable 0.5s or 5s Resolution: 6 digits in 0.5s; 7 digits in 5s Accuracy: ±1 digit ± timebase accuracy Timebase Accuracy: ±10ppm initial error; ±5ppm/year ageing rate; typically less then 0.5ppm/ o C. Adjustment point for closed-case recalibration SWEEP MODES EXTERNAL Input Impedance: 10k Ω Input Sensitivity: 0 to 3V for 1000:1 sweep Max. Input Voltage: ±10V Sweep Linearity: Better than 1% Max. Slew Rate: 0.1V/us INTERNAL (TG330 only) Sweep Range: 1000:1 within each range. Sweep Rate: Adjustable, typically 20ms to 20 secs. Sweep Mode: Linear or logarithmic. Sweep start and stop frequencies displayed at the press of a but- ton. Sweep Output: 3V ramp from 600 Ω. AMPLITUDE MODULATION (TG330 only) Depth: Variable 0 to 100% typical. Frequency: 400Hz (internal). DC to 20kHz (external). External Sensitivity: Approximately 2V peak-to-peak for 50% mod- ulation. Input impedance 40k Ω. GENERAL CASING Moulded ABS case with tilt stand. POWER REQUIREMENTS Input Voltage: 220 to 240 volts AC nominal 50/60Hz or 110 to 120 volts AC nominal 50/60Hz by rear panel adjustment. Installation category II. Power Consumption: 25VA max. TEMPERATURE & ENVIRONMENTAL Operating Temp. Range: +5 o C to +40 o C, 20% to 80% RH. Storage Temp. Range: -10 o C to +65 o C Environmental: Indoor use at altitudes up to 2000m. Pollution degree 2. SIZE 260(W) x 88(H) x 235(D)mm (10.2 x 3.4 x 9.2"), excluding handle and feet. WEIGHT 1.9kg (4.2lb) SAFETY Complies with EN61010-1. EMC Complies with EN61326. seven digit 120MHz external frequency counter internal sweep generator, amplitude modulation 82100-0095 |
Similar Part No. - TG315 |
|
Similar Description - TG315 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |