Electronic Components Datasheet Search |
|
HFBR-1515BZ Datasheet(PDF) 4 Page - AVAGO TECHNOLOGIES LIMITED |
|
HFBR-1515BZ Datasheet(HTML) 4 Page - AVAGO TECHNOLOGIES LIMITED |
4 / 11 page 4 Figure 1. Typical forward voltage vs. drive current Figure 2. Typical normalized optical power vs. drive current Figure 3. Typical normalized optical spectra 2.5 110 100 IF,DO – TRANSMITTER DRIVE CURRENT – mA 2.3 2.1 1.9 1.7 1.5 -40 °C 0 °C 25 °C 70 °C 85 °C 10 110 100 IF,DO – TRANSMITTER DRIVE CURRENT – mA 0 -10 -20 -30 -40 -40 °C 25 °C 85 °C 1.4 610 650 690 WAVELENGTH – nm 1.2 0.8 0.4 0.2 0 -40 °C 0 °C 630 670 0.6 1.0 25 °C 70 °C 85 °C Peak Output Power 0 °C to +70°C unless otherwise note Model Number Symbol Min. Max. Unit Condition Reference HFBR-1505AZ SERCOS PT –10.5 –5.5 dBm POF, IF, dc = 35 mA Notes 2, 3, 11 –7.5 –3.5 POF, IF, dc = 60 mA Figure 2 –18.0 –10 HCS®, IF, dc = 60 mA HFBR-1515BZ PROFIBUS –10.5 –5.5 POF, IF, dc = 35 mA Notes 2, 3, 11 –7.5 –3.5 POF, IF, dc = 60 mA Figure 2 –18.0 –8.5 HCS®, IF, dc = 60 mA HFBR-1505CZ INTERBUS-S –6.2 0.0 POF, IF, dc = 60 mA Notes 3, 8, 9 –16.9 –8.5 HCS®, IF, dc = 60 mA Figure 2 Notes: 1. Typical data at 25˚C. 2. Optical power measured at the end of 0.5 meters of 1 mm diameter plastic optical fiber with a large area detector. 3. Minimum and maximum values for PT over temperature are based on a fixed drive current. The recommended drive circuit has temperature compensation which reduces the variation in PT over temperature, refer to Figures 4 and 6. 4. Thermal resistance is measured with the transmitter coupled to a connector assembly and fiber, and mounted on a printed circuit board. 5. To further reduce the thermal resistance, the cathode trace should be made as large as is consistent with good RF circuit design. 6. For IF,PK > 60 mA, the duty factor must maintain IF,AVG ≤ 60 mA and pulse width ≤ 1 µs. 7. 1.6 mm below seating plane. 8. Minimum peak output power at 25˚C is –5.3 dBm (POF) and –16.0 dBm (HCS®) for 1505CZ series only. 9. Optical power measured at the end of 1 meter of 1 mm diameter plastic or 200 µm hard clad silica optical fiber with a large area detector. 10. Pins 1 and 4 are for mounting and retaining purposes, but are electrically connected; pins 5 and 6 are electrically isolated. It is recommended that pins 1, 4, 5, and 6 all be connected to ground to reduce coupling of electrical noise. 11. Output power with 200 µm hard clad silica optical fiber assumes a typical –10.5 dB difference compared to 1 mm plastic optical fiber. |
Similar Part No. - HFBR-1515BZ |
|
Similar Description - HFBR-1515BZ |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |