Electronic Components Datasheet Search |
|
MSD1260-822MLD Datasheet(PDF) 2 Page - Coilcraft lnc. |
|
MSD1260-822MLD Datasheet(HTML) 2 Page - Coilcraft lnc. |
2 / 3 page US UK Taiwan China Singapore +1-847-639-6400 sales@coilcraft.com +44-1236-730595 sales@coilcraft-europe.com +886-2-2264 3646 sales@coilcraft.com.tw +86-21-6218 8074 sales@coilcraft.com.cn + 65-6484 8412 sales@coilcraft.com.sg © Coilcraft Inc. 2013 This product may not be used in medical or high risk applications without prior Coilcraft approval. Specification subject to change without notice. Please check web site for latest information. Coupled Inductors – MSD1260 Series Document 528-2 Revised 01/13/12 Document 528-2 Coupling Leakage Irms (A) Part Inductance2 DCR max3 SRF typ4 coefficient Inductance5 Isat6 both one number1 (µH) (Ohms) (MHz) typ typ (µH) (A) windings7 winding8 MSD1260-472ML_ 4.7 ±20% 0.036 32.0 0.98 0.20 10.3 3.16 4.47 MSD1260-562ML_ 5.6 ±20% 0.040 31.0 0.98 0.20 9.66 3.00 4.24 MSD1260-682ML_ 6.8 ±20% 0.048 28.0 0.98 0.24 9.21 2.75 3.88 MSD1260-822ML_ 8.2 ±20% 0.052 25.0 0.98 0.25 8.55 2.63 3.72 MSD1260-103ML_ 10 ±20% 0.060 22.0 0.99 0.26 7.40 2.45 3.46 MSD1260-123ML_ 12 ±20% 0.074 21.0 0.99 0.28 6.86 2.21 3.12 MSD1260-153ML_ 15 ±20% 0.085 17.6 0.99 0.32 6.09 2.06 2.92 MSD1260-183ML_ 18 ±20% 0.097 17.0 0.99 0.40 5.30 1.93 2.73 MSD1260-223ML_ 22 ±20% 0.116 15.0 0.98 0.68 5.01 1.76 2.49 MSD1260-273ML_ 27 ±20% 0.124 13.6 0.99 0.50 4.66 1.70 2.41 MSD1260-333ML_ 33 ±20% 0.134 12.7 0.99 0.65 4.22 1.64 2.32 MSD1260-393ML_ 39 ±20% 0.142 11.7 0.99 1.09 3.80 1.59 2.25 MSD1260-473ML_ 47 ±20% 0.174 8.7 0.99 0.80 3.25 1.44 2.03 MSD1260-563ML_ 56 ±20% 0.198 7.6 0.99 0.75 3.07 1.35 1.91 MSD1260-683ML_ 68 ±20% 0.216 6.1 >0.99 0.57 2.83 1.29 1.83 MSD1260-823ML_ 82 ±20% 0.274 5.3 0.99 1.52 2.55 1.15 1.62 MSD1260-104ML_ 100 ±20% 0.322 5.0 0.99 1.41 2.20 1.06 1.50 MSD1260-124KL_ 120 ±10% 0.418 4.4 0.99 1.34 2.05 0.93 1.31 MSD1260-154KL_ 150 ±10% 0.476 4.0 0.99 1.52 1.82 0.87 1.23 MSD1260-184KL_ 180 ±10% 0.536 3.6 0.99 1.80 1.60 0.82 1.16 MSD1260-224KL_ 220 ±10% 0.691 3.2 >0.99 1.60 1.51 0.72 1.02 MSD1260-274KL_ 270 ±10% 0.806 2.8 >0.99 2.23 1.41 0.67 0.95 MSD1260-334KL_ 330 ±10% 1.09 2.5 >0.99 2.39 1.28 0.57 0.81 MSD1260-394KL_ 390 ±10% 1.20 2.3 >0.99 3.72 1.16 0.55 0.77 MSD1260-474KL_ 470 ±10% 1.59 2.1 >0.99 2.89 1.00 0.48 0.67 MSD1260-564KL_ 560 ±10% 1.81 2.0 >0.99 2.55 0.95 0.45 0.63 MSD1260-684KL_ 680 ±10% 2.06 1.8 >0.99 5.76 0.88 0.42 0.59 MSD1260-824KL_ 820 ±10% 2.65 1.5 >0.99 2.86 0.79 0.37 0.52 MSD1260-105KL_ 1000 ±10% 3.06 1.2 >0.99 4.32 0.69 0.34 0.49 1. When ordering, please specify termination and packaging codes: MSD1260-105KLD Termination: L = RoHS compliant matte tin over nickel over phos bronze. Special order: T = RoHS tin-silver-copper (95.5/4/0.5) or S = non-RoHS tin-lead (63/37). Packaging: D = 13 ″ machine-ready reel. EIA-481 embossed plastic tape (500 parts per full reel). B = Less than full reel. In tape, but not machine ready. To have a leader and trailer added ($25 charge), use code letter D instead. 2. Inductance shown for each winding, measured at 100 kHz, 0.1 Vrms, 0 Adc on an Agilent/HP 4284A LCR meter or equivalent. When leads are connected in parallel, inductance is the same value. When leads are connected in series, inductance is four times the value. 3. DCR is for each winding. When leads are connected in parallel, DCR is half the value. When leads are connected in series, DCR is twice the value. 4. SRF measured using an Agilent/HP 4191A or equivalent. When leads are connected in parallel, SRF is the same value. 5. Leakage Inductance is for L1 and is measured with L2 shorted. 6. DC current, at which the inductance drops 30% (typ) from its value without current. It is the sum of the current flowing in both windings. 7. Equal current when applied to each winding simultaneously that causes a 40°C temperature rise from 25°C ambient. See temperature rise calcu- lation. 8. Maximum current when applied to one winding that causes a 40°C temperature rise from 25°C ambient. See temperature rise calculation. 9. Electrical specifications at 25°C. Refer to Doc 639 “Selecting Coupled Inductors for SEPIC Applications.” Refer to Doc 362 “Soldering Surface Mount Components” before soldering. Coupled Inductor Core and Winding Loss Calculator This web-based utility allows you to enter frequency, peak-to-peak (ripple) current, and Irms current to predict temperature rise and overall losses, including core loss. Go to online calculator. |
Similar Part No. - MSD1260-822MLD |
|
Similar Description - MSD1260-822MLD |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |