Electronic Components Datasheet Search |
|
ADC084S101 Datasheet(PDF) 9 Page - Texas Instruments |
|
|
ADC084S101 Datasheet(HTML) 9 Page - Texas Instruments |
9 / 28 page 2 1 f 2 6 f 2 2 f 10 ‡ A A + + A log 20 = THD ADC084S051 www.ti.com SNAS261F – NOVEMBER 2004 – REVISED MARCH 2013 TOTAL HARMONIC DISTORTION (THD) is the ratio, expressed in dB or dBc, of the rms total of the first five harmonic components at the output to the rms level of the input signal frequency as seen at the output. THD is calculated as where • Af1 is the RMS power of the input frequency at the output and Af2 through Af6 are the RMS power in the first 5 harmonic frequencies. (2) THROUGHPUT TIME is the minimum time required between the start of two successive conversion. It is the acquisition time plus the conversion and read out times. In the case of the ADC084S051, this is 16 SCLK periods. Copyright © 2004–2013, Texas Instruments Incorporated Submit Documentation Feedback 9 Product Folder Links: ADC084S051 |
Similar Part No. - ADC084S101 |
|
Similar Description - ADC084S101 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |