1 / 3 page Oxygen sensor module FCX-M Data sheet FCX-M series Model ■Specifications Item FCX-MP-F-AC FCX-MQ-F-AC FCX-MV-F FCX-MV-F-AC FCX-MW-F FCX-MW-F-AC FCX-MWGP-2A-F FCX-MEP2-F FCX-MEP2-F-AC Measurement range 50 to 1000ppmO2 0.05 to 1 %O2 0.1 to 25 %O2 0.1 to 95 %O2 75 to 95 %O2 0.1 to 25 %O2 Accuracy +/-5%FS +/-5%FS +/-1%FS +/-0.5%FS +/-2%O2 +/-1%FS 50 to 1000 mV 50 to 1000 mV 1 to 250 mV 0 to 2669 mV 1235 to 2669 mV 4 to 20 mA Output (Logarithmic) Vout=-999.5x10 3 x LN 1- Vout= -99.5x10 3 x LN 1- Vout= -891x LN 1- Output= -57x LN 1- +4 Response time * 3 90sec. (for 90% value) 30sec. (for 90% value) 30sec. (for 90% value) Power supply * 4 DC5+/-0.2V DC5+0.1/-0.25V DC12+/-3V Power consumption 5W max. 4W max. 3W Operating temperature -10 to 50 deg.C 0 to 60 deg.C -10 to 50 deg.C Operating humiditiy * 5 0 to 85%RH 40 to 85%RH 0 to 85%RH Dimensions 50x16x104 mm 40x23x80 mm 45x20x52 mm Weight Approx. 65grams Approx. 40grams Approx. 40grams Item FCX-MVL-F FCX-MVL-F-AC FCX-MWL-F FCX-MWL-F-AC Measurement range 0.1 to 25 %O2 0.1 to 95 %O2 Accuracy +/-1%FS +/-1%FS 1 to 250 mV 1 to 950 mV Output (Linear) Vout= 10xO2% Response time * 3 30sec. (for 90% value) Power supply * 4 DC5+/-0.2V Power consumption 5W max. Operating temperature -10 to 50 deg.C Operating humiditiy * 5 0 to 85%RH Dimensions 50x38x104 mm Weight Approx. 120grams *1 Depends on operating environment. *2 Annual calibration or maintenance still recommended. *3 From 10 to 90% step change. *4 Regurated DC power supply.The current capacity must be 1A. *5 Without vapour condensation. ■Features ・ High accuracy ・ Long life (More than 3 years in normal air) *1 ・ Continues calibration and maintenance not required *2 ・ Calibration gas not required ・ From ppm to 95%O2, wide measurement range ・ No interfarance to media ・ No pressure dependence ■Applications ・ Oxygen concentrator ・ Nitrogen purifier ・ Alarm for oxygen shortage ・ Culture oven ro Incubator ・ Combustion control ・ Soldering system Instruction for use ; 1. Sensor modules are calibrated with N2-O2 balance gases. Other gases may affect the sensor performance by increase errors. 2. Do NOT separate the sensing element from the circuit board and lead wires length must be remained unchanged. 3. Do NOT use in harsh environmental conditions containing halogen atoms(F,Cl,Br) , SOx ,Nox or H2S which make the sensor inferior in a short time. 4. Flammable gases ,such as H2 ,CO ,methane or Alcohol make a big error. And please note that the temperature at the sensing part goes uo to 450 degrees C during the operation,which may exceed the flash point and cause explosion. 5. Silicone gas or vapour including Siloxane also make the sensor inferior in a short time. 6. Dust or oil mist cause failures of the products,errors or a slow response. They must be eliminated with a filter. 7. Water drop's contact may give a damage to sensor. It must be eliminated with a filter. 8. Temperature at the sensor mesh surface reach 50~80 degrees C during operation. Please take precautions against burning yourseif. 9. A strong shock such as drop may cut internal wires or break the sensor pellet which is made of ceramic. Do NOT apply a shock of 10G or more to the sensor. 10. The warranty period is one year from the ex-factory date. This warranty does NOT apply to the sensors as follows ; 1) There are any defects to faults caused by an improper dealing during the transpotation after Fujikura has delivered the sensor to place where the buyer had instructed. 2) There are any defects or faults caused by the buyer's misuses ,abuse or neglect. 3) The buyer fixed or remake the sensors. 4) There are any indentical or consequential damages which are given in the usage. 5) There are any defects or faults caused by natural disasters such as life ,earthquake, flood or thunder. 11. Fujikura's oxygen sensors are NOT developed ,designed ,manufactured ,sold , intended or authorized for use as components in systems intended for the surgical implant into the body ,other applications intended to support or sustain life ,fail-safe applications in which the failures ,breakages or where misused of the sensors could create a situation where personal injury or death ,explosion or fire ,or serious social damage may occur. Fujikura and its subcontractors and distributors accept NO responsibility the buyer's selection and use of Fujikura's oxygen sensors without Fujikura's written approval in any such unintended or unauthorized and situation where personal injury or death ,explosion or fire ,or serious social damage may occur. 12. A fail-safe design is strongly required when customers use the sensor in medecal applications or alarm systems for oxygen shortage even except above. If you have any questions regarding technical issues or specifications, please contact us. Note ; Please read above instructions before using the sensor. Fujikura reserves right to change specifications without notice. Fujikura Ltd. Sensor Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 E-mail : sensor@fujikura.co.jp ppmO2 106 %O2 100 %O2 100 %O2 100 RoHS compliance |
Similar Part No. - FCX-MWGP-2A-F |
|
Similar Description - FCX-MWGP-2A-F |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |