Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.COM

X  

HG2-AC100V-F Datasheet(PDF) 8 Page - Panasonic Semiconductor

Part # HG2-AC100V-F
Description  TYPICAL APPLICATIONS
Download  9 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  PANASONIC [Panasonic Semiconductor]
Direct Link  http://www.panasonic.com/industrial/
Logo PANASONIC - Panasonic Semiconductor

HG2-AC100V-F Datasheet(HTML) 8 Page - Panasonic Semiconductor

  HG2-AC100V-F Datasheet HTML 1Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 2Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 3Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 4Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 5Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 6Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 7Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 8Page - Panasonic Semiconductor HG2-AC100V-F Datasheet HTML 9Page - Panasonic Semiconductor  
Zoom Inzoom in Zoom Outzoom out
 8 / 9 page
background image
HG
Discontinued as of August 31, 2012
8
ds_61C08_en_hg: 011111D
2. Terminal socket for DIN rail assembly (with hold-down clip and installation screw)
HG2-Terminal socket for DIN rail assembly (HG2-SFD)
External dimensions
HG2 relay
80
±1
3.150
±.039
69
±1
2.717
±.039
4.5
±0.3
.177
±.012
7.26
±0.2
.286
±.008
.236
±.012
6
±0.3
7.56
±0.2
.298
±.008
58
±1
2.283
±.039
36
±0.6
1.417
±.024
34.5
±0.6
1.358
±.024
34
±0.6
1.339
±.024
9
±0.3
.354
±.012
10
±0.6
.394
±.024
21
±0.6
.827
±.024
.669
±.008
17
±0.2
26
±0.6
1.024
±.024
Hold-down clip
M.157
M4 screw
10.44
±0.2
.411
±.008
.022
±.006
0.56
±0.15
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
Schematic
7
8
5
6
1
4
3
2
With a relay mounted
Note: Hold-down clip is packaged with the terminal socket.
Mounting hole diagram
Tolerance:
0.1 .004
*For direct mounting, use the included installation screw
block.
80
3.150
69
±0.2
2.717
±.008
1.024
±.008
1.024
±.008
34
34
1.339
1.339
2
.079
.394
±.008
26
±0.2
26
±0.2
10
±0.2
2-M.157 screw hole
(or .165
±.004 dia. hole)
2-M4 screw hole
(or 4.2
±0.1 dia. hole)
Panel hole dimensions
for side-by-side installation
HG3-Terminal socket for DIN rail assembly (HG3-SFD)
External dimensions
HG2 relay
80
±1
3.150
±.039
69
±1
2.717
±.039
4.5
±0.3
.177
±.012
7.26
±0.2
.286
±.008
.236
±.012
6
±0.3
7.56
±0.2
.298
±.008
58
±1
2.283
±.039
36
±0.6
1.417
±.024
34.5
±0.6
1.358
±.024
51
±0.6
2.008
±.024
9
±0.3
.354
±.012
10
±0.6
.394
±.024
.827
±.024
21
±0.6
.669
±.008 .669±.008
17
±0.2 17±0.2
43
±0.6
1.693
±.024
Hold-down clip
10.44
±0.2
.411
±.008
.022
±.006
0.56
±0.15
* Installation screw block
(installation screw, hexagonal nut,
spring washer)
M.157
M4 screw
Schematic
4
1
5
2
6
3
7
12
9
11
8
10
With a relay mounted
Note: Hold-down clip is packaged with the terminal socket.
Mounting hole diagram
Tolerance:
0.1 .004
*For direct mounting, use the included installation screw
block.
3.150
80
69
±0.5
2.717
±.020
43
±0.2
51
51
2.008
2.008
2
.079
43
±0.2
1.693
±.008
1.693
±.008
.394
±.008
10
±0.2
2-M.157 screw hole
(or .165
±.004 dia. hole)
2-M4 screw hole
(or 4.2
±0.1 dia. hole)
Panel hole dimensions
for side-by-side installation


Similar Part No. - HG2-AC100V-F

ManufacturerPart #DatasheetDescription
logo
Panasonic Semiconductor
HG2-AC115V PANASONIC-HG2-AC115V Datasheet
222Kb / 5P
   20 AMP POWER RELAY
HG2-AC12V PANASONIC-HG2-AC12V Datasheet
222Kb / 5P
   20 AMP POWER RELAY
More results

Similar Description - HG2-AC100V-F

ManufacturerPart #DatasheetDescription
logo
Panasonic Semiconductor
HL1-HTM-AC240V PANASONIC-HL1-HTM-AC240V Datasheet
151Kb / 7P
   TYPICAL APPLICATIONS
logo
Vectron International, ...
C1300 VECTRON-C1300_09 Datasheet
144Kb / 4P
   Typical Applications
C1310 VECTRON-C1310_07 Datasheet
217Kb / 7P
   Typical Applications
C4650 VECTRON-C4650_05 Datasheet
309Kb / 3P
   TYPICAL APPLICATIONS
C1250 VECTRON-C1250_09 Datasheet
133Kb / 4P
   Typical Applications
C2260 VECTRON-C2260_06 Datasheet
149Kb / 6P
   Typical Applications
logo
Panasonic Semiconductor
AQP812 PANASONIC-AQP812 Datasheet
180Kb / 7P
   TYPICAL APPLICATIONS
logo
Rohm
BA3920 ROHM-BA3920 Datasheet
358Kb / 8P
   Block Diagram of Typical Applications
logo
DIYI Electronic Technol...
BT151 DYELEC-BT151 Datasheet
2Mb / 5P
   Typical applications include motor control
logo
List of Unclassifed Man...
FK-130RH ETC-FK-130RH Datasheet
31Kb / 1P
   Typical Applications / Office Automation Equipments
More results


Html Pages

1 2 3 4 5 6 7 8 9


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com