Electronic Components Datasheet Search |
|
E3X-F51 Datasheet(PDF) 10 Page - Omron Electronics LLC |
|
E3X-F51 Datasheet(HTML) 10 Page - Omron Electronics LLC |
10 / 17 page 11 E3X E3X 11 s VARIABLE HYSTERESIS FUNCTION (E3X-H11) Detection of Plate Level Differences min max min max min max (If detection is impossible with the hysteresis value set to maximum) Refer to the following when using the hysteresis adjuster. Detecting operation is not stable because zone B is within the hysteresis differential range. Reduce the sensitivity of the E3X with the sensitivity adjuster and turn off zone B. Reduce the hysteresis value with the hysteresis adjuster so that zone A will be ON. Reflection of light Reflection of light Reflection of light Large hysteresis differential Small hysteresis differential ON ON ON OFF OFF A ON B OFF A Unstable B Unstable B OFF A ON OFF Set both the sensitivity adjuster and hysteresis adjuster to maximum. Decide the position of the fiber head and that of the sensing object in zone A. Locate the head in zone A and turn the sensitivity adjuster counterclockwise slowly until the stable operation indicator and light reception indicator are OFF (i.e., position E as shown in the illustration). Detection is possible When the head is located in zone B, light reception indicator is lit. Set the hysteresis adjuster to the point where the light reception indicator is lit (i.e., position E as shown in the illustration.) A B (example) min max SENS 1 s Sensitivity adjuster Hysteresis differential adjuster min max NO SL Locate the head in zone A and turn the sensitivity adjuster counterclockwise until the light reception indicator and stable operation indicator are OFF (i.e., position O as shown in the illustration). YES SL YES SL Locate the head in zone B and turn the hysteresis adjuster counterclockwise slowly and make sure that the light reception indicator is lit. YES SL The light reception indicator is lit when the head is located in zone B and the light reception indicator is OFF when the head is located in zone A. (H) min max SENS 1 s (E) Locate the head in zone A and turn the sensitivity adjuster clockwise until the stable operation indicator and light reception indicator are OFF (i.e., position F as shown in the illustration.) Set the hysteresis adjuster to maximum. min max SENS 1 s (G) (F) min max SENS 1 s (G) (E) NO SL NO SL |
Similar Part No. - E3X-F51 |
|
Similar Description - E3X-F51 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |