Back Button HMC-AP001 Datasheet HTML 5Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 6Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 7Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 8Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 9Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 10Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 11Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 12Page - Omron Electronics LLC HMC-AP001 Datasheet HTML 13Page - Omron Electronics LLC Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 14 page
background image
CS1W-SPU01-V2/02-V2
9
Software Package Contents
The WS02-EDMC1-V2 software package contains the following items.
• EDMS Installation Program
The EDMS installation program is used to install the Copy Task Service and EDMS-Console on a computer.
• Microsoft .NET Framework Version 1.1 Redistributable Package
Microsoft .NET Framework Version 1.1 is required to run the SPU-Console. The Redistributable Package provided in the software package can
be used to install .NET Framework on the computer.
• FinsGateway Version 2003
The FinsGateway version 2003 communications middleware is required to run the SPU-Console.
• Operation Manual
The SYSMAC SPU Data Management Middleware User’s Manual (Cat. No. V232) is included in PDF format in the software package.
System requirements
OS
Microsoft Windows 2000 Professional
Microsoft Windows XP Home Edition
Microsoft Windows XP Professional
Microsoft Windows 2003 server
Microsoft Windows Vista
Application platform
(execution environment)
Microsoft .NET Framework version 1.1
Microsoft Data Access Component 2.6 or later
Communications platform
FinsGateway version 2003
Other software requirements
SPU-Console (sold separately) required to input SPU Unit settings.
Registration of applicable SPU Units
SPU Units can be registered by specifying the IP address and name of the Unit
(same for the SPU-Console).
Copy function
Copies files from the Memory Card in a registered SPU Unit to a specified folder on a computer hard
disk. The function is enabled only when two or more is set in the Number of files Field from the SPU-
Console.
Settable number of copies
256 max.
Copy start conditions
Start Button or automatically on computer startup.
Copy timing
Files will be saved to the computer hard disk over the
network automatically when copying is enabled (data
collection has stopped or files have been transferred).
Storage location
Any specified folder
Saved file name
File names can be created automatically using one or
any combination of the following objects: Any text string,
the name of the copy, the name of the source SPU Unit,
the time or date (month, day, year) the file was copied,
consecutive file numbers, the date or time of the start
record, and the date or time of the last record.
Copy monitoring cycle
Settable cycle for monitoring when copying is enabled.
Default: 10 s
Status indicators
Used to check starting, started (monitoring copying),
copying, stopped, and error status conditions.
Log display
Press the Display of log Button to display the operating
status or an error log list that shows the month/day/year,
time, event ID, and description.
Database storage function
Data files that are copied to a specified folder on a computer hard disk are stored in a database. The
function is enabled only when three or more is set in the Number of files Field from the SPU-Console.
Settable number of data base storage
services
65 max.
Database storage start conditions
Start Button or automatically on computer startup.
Storage timing
Files will be automatically stored in the database as soon
as storable files are detected.
Applicable databases
Microsoft Access
2000, 2002, 2003
Microsoft SQL Server
2000, 2005
Oracle Database
10g2
Copy folder monitoring cycle
Settable cycle for monitoring when there are storable
files.
Default: 10 s
Status indicators
Used to check whether storage is in progress (monitor-
ing for storable files) or stopped.
Log display
Press the Display of log Button to display the operating
status or an error log list that shows the month/day/year,
time, and description.
SPU clock synchronization function
The SPU Unit (version 1.2 or later only) and CPU Unit clocks are periodically synchronized with the
computer clock.
Item
Description


Similar Part No. - HMC-AP001

ManufacturerPart #DatasheetDescription
logo
Omron Electronics LLC
HMC-AP001 OMRON-HMC-AP001 Datasheet
8Mb / 70P
   Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
HMC-AP001 OMRON-HMC-AP001 Datasheet
344Kb / 15P
   CPU Selection
HMC-AP001 OMRON-HMC-AP001 Datasheet
344Kb / 15P
   CJ1 Ordering Guide
HMC-AP001 OMRON-HMC-AP001 Datasheet
220Kb / 8P
   CJ1 Programmable Controllers
HMC-AP001 OMRON-HMC-AP001 Datasheet
638Kb / 5P
   Operator Interfaces/HMIs NS
More results

Similar Description - HMC-AP001

ManufacturerPart #DatasheetDescription
logo
Analog Devices
AD7891 AD-AD7891_17 Datasheet
394Kb / 21P
   8-Channel, 12-Bit High Speed Data Acquisition System
logo
Omron Electronics LLC
WT30 OMRON-WT30 Datasheet
352Kb / 8P
   Construct a Wireless System for ON/OFF Data Collection That Is Ideal for Monitoring Production Site Equipment
logo
Analog Devices
AD7891 AD-AD7891_04 Datasheet
1Mb / 20P
   LC2MOS 8-Channel, 12-Bit High Speed Data Acquisition System
REV. D
AD7891AP AD-AD7891AP Datasheet
316Kb / 20P
   LC2MOS 8-Channel, 12-Bit High Speed Data Acquisition System
REV. D
AD7891 AD-AD7891 Datasheet
173Kb / 20P
   LC2MOS 8-Channel, 12-Bit High Speed Data Acquisition System
REV. A
AD7891YSZ-2 AD-AD7891YSZ-2 Datasheet
1Mb / 20P
   LC2MOS 8-Channel, 12-Bit High Speed Data Acquisition System
REV. D
logo
Infineon Technologies A...
ESD114-U1-02 INFINEON-ESD114-U1-02 Datasheet
975Kb / 14P
   ESD / Transient protection of high speed data lines exceeding
logo
Analog Devices
AD7891 AD-AD7891_15 Datasheet
1Mb / 20P
   LC MOS 8-Channel, 12-Bit High Speed Data Acquisition System
REV. D
logo
Micro Linear Corporatio...
ML6622 MICRO-LINEAR-ML6622 Datasheet
94Kb / 6P
   High-Speed Data Quantizer
logo
Samtec, Inc
HDLSP-035-1000 SAMTEC-HDLSP-035-1000 Datasheet
396Kb / 1P
   HIGH-DENSITY/HIGH-SPEED CABLE SYSTEM
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com