Electronic Components Datasheet Search |
|
E5ZE-CBL200 Datasheet(PDF) 11 Page - Omron Electronics LLC |
|
E5ZE-CBL200 Datasheet(HTML) 11 Page - Omron Electronics LLC |
11 / 32 page H8PS 11 Nomenclature ■ Displays ■ Operation Keys 8-output Models 16-/32-output Models Display Details No. Display color Description (1) Orange Lit while cam outputs are ON. (2) Red PV: Lit while the present angular position or speed is displayed in main display. SV: Lit while the setting value is displayed in main display. (3) Orange Lit while the start input is ON in Run or Test Mode. Not lit when an error occurs. (4) Orange Displays Encoder present angular position, direction, and speed guidelines. (5) Green Displays the bank number that is running in Run or Test Mode and the bank number selected in Programming Mode. (6) Green Displays the cam number for the angle setting displayed on sub- display. (7) Green Displays the step number for the angle setting displayed on sub- display. (8) Orange Lit while the All Protection function is enabled. (9) Orange The indicator for the selected mode is lit. PRG: Programming Mode TST: Test Mode RUN: Run Mode (10) Red Displays the present angular position or the speed and settings being made. (11) Red Displays units for the angle or the speed displayed on main display. (12) Red Lit while using an Encoder with a resolution of 256 if 256 ° display is selected. (13) Green Displays units for the angle or the speed displayed on sub-display. (14) Green Displays the speed or the ON/OFF angle settings. (15) Green Indicates whether main display displays the ON or OFF angle setting. (16) Green Lit while setting the Advance Angle Compensation (ADV) Function. CAM STEP (1) Cam output indicators (2) PV/SV indicator (4) Rotation display monitor (6) Cam No. display (7) Step No. display (8) All protect indication (9) Mode indicator (10) Main display (11) Unit indication (13) Unit indication (12) 256 indication (14) Sub-display (15) ON/OFF indication (16) ADV indication 12345678 PRG TST RUN CAM STEP (8) All protect indication (9) Mode indicator (10) Main display (11) Unit indication (13) Unit indication (12) 256 indication (14) Sub-display (15) ON/OFF indication (16) ADV indication 123456789 10 PRG TST RUN 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 (3) Start input indication (5) Bank No. display (2) PV/SV indicator (4) Rotation display monitor (6) Cam No. display (7) Step No. display (1) Cam output indicators 8-output Models 16-/32-output Models Operation Key Details No. Description 1 Displays program details in Run Mode. 2 Selects the cam number with Keys. 3 Selects the step number with Keys. 4 Selects the bank number. 5 Selects the ON angle, or OFF angle 6 Writes the set data to memory. 7 Changes the angle or other setting value with Keys. 8 Connects the Cam Positioner to a personal computer via USB cable (order separately) for programming with the Support Software (order separately). 9 Moves to the screen for clearing settings 10 Designates the current angle of the machine (Encoder) as the origin (0 °). 11 Programming or Test Mode: Press to shift to the ADV function setting screen. Programming Mode: Press and hold at least 3 s to shift to the Function Setting Mode. Run Mode: Press and hold at least 5 s to enable/disable the All Protection function. 12 Switches modes. Programming Mode (PRGM): Used to write cam programs, set the ADV function, etc. Test Mode (TEST): Used to modify settings while the Encoder is running. Run Mode (RUN): Used for normal operation and to check the cam program. 13 Select the method used for programming cams. Teaching: ON/OFF Angles can be set based on actual machine (Encoder) operation. Manual: ANGLE Keys can be used to set ON/OFF angles. 14 Sets the H8PS rotation direction (rotation display monitor, etc.) to the machine (Encoder) rotation direction. 15 Sets the resolution of the connected Encoder. Also sets the unit for angle display when using an Encoder with a resolution of 256. ORIGIN CHECK CAM STEP CLEAR ANGLE ADV WRITE DO NOT USE. CW CCW PLS/R ANG DSPL CAM STEP 1. CHECK key 2. CAM keys 3. STEP keys 5. ON/OFF key 6. WRITE key 7. ANGLE keys 9. CLEAR key 10. ORIGIN key 13. Programming mode switch 15. Encoder resolution switch 12. Mode switch PRGM TEST RUN TCH MAN ON OFF OFF ON 4 3 2 1 OFF OFF ON ON OFF ON OFF 720 360 360 360 360 256 256 256 ON 4 3 11. ADV key 14. Rotation direction switch 1. CHECK key 2. CAM keys 3. STEP keys 5. ON/OFF key 6. WRITE key 7. ANGLE keys 9. CLEAR key 10. ORIGIN key 8. USB connector 4. BANK key ON OFF OFF ON 4 3 2 1 OFF OFF ON ON OFF ON OFF 720 360 360 360 360 256 256 256 ON 4 3 ORIGIN CHECK CAM STEP CLEAR ANGLE ADV WRITE DO NOT USE. CW CCW PLS/R ANG DSPL CAM STEP PRGM TEST RUN TCH MAN BANK 13. Programming mode switch 15. Encoder resolution switch 12. Mode switch 14. Rotation direction switch 11. ADV key |
Similar Part No. - E5ZE-CBL200 |
|
Similar Description - E5ZE-CBL200 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |