Electronic Components Datasheet Search |
|
MAT03AH Datasheet(PDF) 10 Page - Analog Devices |
|
MAT03AH Datasheet(HTML) 10 Page - Analog Devices |
10 / 12 page –10– REV. B MAT03 Figure 19. Digitally Programmable Current Pump—INL Error as Digital Code The full-scale output of the DAC08, IOUT, is a linear function of IREF IFR = 256 256 × I REF, and IOUT + IOUT = IREF 256 256 The current mirror output is IOUT – I OUT = 1, so that if IREF = 2 mA: I = 2 IOUT – 1.992 mA = 2 Input Code 256 (2 mA) – 1.992 mA. DIGITAL CURRENT PUMP CODING Digital Input B1 . . . B8 Output Current FULL RANGE 1111 1111 I = 1.992 mA HALF-RANGE 1000 0000 I = 0.008 mA ZERO-SCALE 0000 0000 I = –1.992 mA |
Similar Part No. - MAT03AH |
|
Similar Description - MAT03AH |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |