9 / 14 page 9 of 14 RF3932 DS120406 7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical support, contact RFMD at (+1) 336-678-5570 or customerservice@rfmd.com. Bias Instruction for RF3932 Evaluation Board ESD Sensitive Material. Please use proper ESD precautions when handling devices of evaluation board. Evaluation board requires additional external fan cooling. Connect all supplies before powering evaluation board. 1. Connect RF cables at RFIN and RFOUT. 2. Connect ground to the ground supply terminal, and ensure that both the VG and VD grounds are also connected to this ground terminal. 3. Apply -8V to VG. 4. Apply 48V to VD. 5. Increase VG until drain current reaches 220mA or desired bias point. 6. Turn on the RF input. |
Similar Part No. - RF3932_12 |
|
Similar Description - RF3932_12 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |