| IRM-3756T |
|
||
|
EVERLIGHT |
|
4 page
EVERLIGHT ELECTRONICS CO.,LTD. Everlight Electronics Co., Ltd. http:\\www.everlight.com Rev 1 Page: 4 of 10 Device No:SZDMO-037-031 Prepared date:31-August-2007 Prepared by: Liuyan IRM-37xxT SERIES Test Method: The specified electro-optical characteristics is satisfied under the following Conditions at the controllable distance. Measurement place A place that is nothing of extreme light reflected in the room. External light Project the light of ordinary white fluorescent lamps which are not high Frequency lamps and must be less then 10 Lux at the module surface. (Ee≦10Lux) Standard transmitter A transmitter whose output is so adjusted as to Vo=400mVp-p and the output Wave form shown in Fig.-1.According to the measurement method shown in Fig.-2 the standard transmitter is specified. However , the infrared photodiode to be used for the transmitter should be λp=940nm,Δλ=50nm. Also, photodiode is used of PD438B(Vr=5V). (Standard light / Light source temperature 2856 °K). Measuring system According to the measuring system shown in Fig.-3 Block Diagram: Vs Modulated IR signal min 10 pulses Carrier frequency f0 OUT IN GND Input CGA & filter Demodulator Oscillator AGC/ATC & digital control µC |