| SY100E241JC |
|
||
|
MICREL |
|
3 page
3 SY10E241 SY100E241 Micrel, Inc. M9999-032206 hbwhelp@micrel.com or (408) 955-1690 TRUTH TABLE SEL0 SEL1 Function L L Load L H Hold H X Shift (Dn to Dn+1) VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0 °CTA = +25°CTA = +85°C Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition fSHIFT Max. Shift Frequency 700 900 — 700 900 — 700 900 — MHz — tPD Propagation Delay to Output ps — CLK 625 750 975 625 750 975 625 750 975 MR 600 725 975 600 725 975 600 725 975 tS Set-up Time ps — D 175 25 — 175 25 — 175 25 — SEL0 (SHIFT)350 200 — 350 200 — 350 200 — SEL1 (HOLD/LOAD) 400 250 — 400 250 — 400 250 — S-IN 125 –100 — 125 –100 — 125 –100 — tH Hold Time ps — D 200 –25 — 200 –25 — 200 –25 — SEL0 (SHIFT) 100 –200 — 100 –200 — 100 –200 — SEL1 (HOLD/LOAD) 50 –250 — 50 –250 — 50 –250 — S-IN 300 100 — 300 100 — 300 100 — tRR Reset Recovery Time 900 600 — 900 600 — 900 600 — ps — tPW Minimum Pulse Width 400 —— 400 —— 400 —— ps — CLK, MR tskew Within-Device Skew — 60 —— 60 —— 60 — ps 1 tr Rise/Fall Time 300 525 800 300 525 800 300 525 800 ps — tf 20% to 80% AC ELECTRICAL CHARACTERISTICS DC ELECTRICAL CHARACTERISTICS VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND TA = 0 °CTA = +25°CTA = +85°C Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition IIH Input HIGH Current —— 150 —— 150 —— 150 µA — IEE Power Supply Current mA — 10E — 125 150 — 125 150 — 125 150 100E — 125 150 — 125 150 — 144 173 Note: 1. Within-device skew is defined as identical transitions on similar paths through a device. |