7 / 16 page 50-607 Kotron Model 810 RF Point Level Sensor 4 Figure 5 Mounting Screws Green Ground Screw I.S. Ground Figure 6 2.5 Wiring All power and control connections are made at the terminal strip within the amplifier enclosure, EXCEPT GROUNDING. Power grounding must be made at green ground screw on the housing base. 16AWG wire is recommended for power and control circuits. NOTE: There are special wiring requirements for intrinsic safety. Observe all local electrical codes and proper wiring procedures. Caution: This unit contains CMOS electronics which may be damaged by static electricity. Do not touch any semi- conductor devices unless you are properly grounded. PROCEDURE: 1. Make sure the power source is turned off. 2. Unscrew and remove housing cover. 3. Pull power supply and control wires through conduit ground connection. 4. Connect green ground wire to green ground screw located in the base of the housing. NOTE: If separate I.S. ground is required in this application, then I.S. ground (conventionally, blue #12 wire) should be connected to the barrier at this time. Refer to NEC and agency guidelines. 5. After grounding is complete, connect AC power leads to the HOT and COM terminals as marked. Refer to Figure 6. NOTE: For DC supply voltage connect DC+ to HOT and DC– to COM. 6. Connect control circuit leads to relay terminals. Refer to Figure 6. Make sure the load to be controlled is within the relay's rated capacity. 7. Prevent moisture seepage into housing by installing an approved seal-drain fitting in the conduit run leading to the unit. 8. Select operating mode. (Refer to OPERATING MODE SELECTION on page 5 for detailed information.) Make sure that the fail-safe switches are in the correct position for your selection. Refer to Figure 7 and the RELAY WIRING CHART on page 5. Caution: In hazardous areas, do NOT power the unit until the conduit is sealed and the enclosure cover is screwed down securely. 9. Installation is complete. Replace housing cover. |
Similar Part No. - 810-0205-Y02 |
|
Similar Description - 810-0205-Y02 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |