Electronic Components Datasheet Search |
|
PCA9671DB Datasheet(PDF) 9 Page - NXP Semiconductors |
|
PCA9671DB Datasheet(HTML) 9 Page - NXP Semiconductors |
9 / 35 page PCA9671 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2010. All rights reserved. Product data sheet Rev. 2 — 29 July 2010 9 of 35 NXP Semiconductors PCA9671 Remote 16-bit I/O expander for Fm+ I2C-bus with reset 7.2 Software Reset call, and device ID addresses Two other different addresses can be sent to the PCA9671. • General Call address: allows to reset the PCA9671 through the I2C-bus upon reception of the right I2C-bus sequence. See Section 7.2.1 “Software Reset” for more information. • Device ID address: allows to read ID information from the device (manufacturer, part identification, revision). See Section 7.2.2 “Device ID (PCA9671 ID field)” for more information. 7.2.1 Software Reset The Software Reset Call allows all the devices in the I2C-bus to be reset to the power-up state value through a specific formatted I2C-bus command. To be performed correctly, it implies that the I2C-bus is functional and that there is no device hanging the bus. The Software Reset sequence is defined as following: 1. A START command is sent by the I2C-bus master. 2. The reserved General Call I2C-bus address ‘0000 000’ with the R/W bit set to logic 0 (write) is sent by the I2C-bus master. 3. The PCA9671 device(s) acknowledge(s) after seeing the General Call address ‘0000 0000’ (00h) only. If the R/W bit is set to logic 1 (read), no acknowledge is returned to the I2C-bus master. 4. Once the General Call address has been sent and acknowledged, the master sends 1 byte. The value of the byte must be equal to 06h. a. The PCA9671 acknowledges this value only. If the byte is not equal to 06h, the PCA9671 does not acknowledge it. If more than 1 byte of data is sent, the PCA9671 does not acknowledge any more. 5. Once the right byte has been sent and correctly acknowledged, the master sends a STOP command to end the Software Reset sequence: the PCA9671 then resets to the default value (power-up value) and is ready to be addressed again within the specified bus free time. If the master sends a Repeated START instead, no reset is performed. Fig 10. General Call address Fig 11. Device ID address 0 002aac155 0 0 0 0 0 0 0 R/W R/W 002aab638 1 1 1 1 1 0 0 |
Similar Part No. - PCA9671DB |
|
Similar Description - PCA9671DB |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |