Electronic Components Datasheet Search |
|
V23047-A1012-A511 Datasheet(PDF) 1 Page - Tyco Electronics |
|
V23047-A1012-A511 Datasheet(HTML) 1 Page - Tyco Electronics |
1 / 3 page Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical para- meters, test conditions and processing information only to be used together with the 'Definitions' section in the cat- alogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. General Purpose Relays 1 SCHRACK Safety Relay SR2M Approvals V REG.-Nr. 116064, Z E214024, T 968/EZ 111.03/05 Technical data of approved types on request Contact data Contact configuration 1 NO contact and 1 NC contact or 2 CO contacts1) Contact set single contact, forcibly guided 1 NC + 1NO: type A according to EN 50205 2 CO: type B according to EN 50205 Type of interruption micro disconnection Rated voltage / max. switching voltage AC 250 / 400 VAC Rated current 6 A Maximum breaking capacity AC 1500 VA Contact material AgNi Minimum contact load 10 mA / 5 V Contact resistance w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Rated frequency of operation with / without load 6 min-1 / 300 min-1 1) According EN50205 only 1NO / 1NC (11-14 and 22-21 or 12-11 and 21-24) shall be used as forcibly guided contacts. Contact ratings Type Contact Load*) Ambient Cycles temp. [°C] UL 508 V23047-A1…-A501 1 NO B300 pilot duty 40°C 6x103 V23047-A1…-A501 1 NO R300 pilot duty 40°C 6x103 V23047-A1…-A511 1 NO B300 pilot duty 40°C 6x103 V23047-A1…-A511 1 NO R300 pilot duty 40°C 6x103 *) load on one pole Coil data Rated coil voltage range DC coil 5...110 VDC Operative range to IEC 61810 2 Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.8 0.5 35,7 +10% 700 006 6 4.5 0.6 51 +10% 706 009 9 6.8 0.9 116 +10% 698 012 12 9.0 1.2 206 +10% 699 015 15 11.3 1.5 321 +10% 700 018 18 13.5 1.8 483 +10% 671 021 21 15.8 2.1 630 +10% 700 024 24 18.0 2.4 823 +10% 700 036 36 27.0 3.6 1851 +10% 700 n 2 pole safety relay with either 1NO+1NC or 2CO contacts n Forcibly guided contacts according to EN 50205 n Rated current 6 A n 6 kV surge resistance between poles Applications Emergency shut-off, machine control, elevator and escalator control, light barrier control F0188-D |
Similar Part No. - V23047-A1012-A511 |
|
Similar Description - V23047-A1012-A511 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |