Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.COM

X  

PS-DA0211-02S Datasheet(PDF) 4 Page - Power Systems GmbH+Co.KG

Part # PS-DA0211-02S
Description  DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
Download  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  POWER-SYSTEMS [Power Systems GmbH+Co.KG]
Direct Link  http://www.power-systems.de
Logo POWER-SYSTEMS - Power Systems GmbH+Co.KG

PS-DA0211-02S Datasheet(HTML) 4 Page - Power Systems GmbH+Co.KG

  PS-DA0211-02S Datasheet HTML 1Page - Power Systems GmbH+Co.KG PS-DA0211-02S Datasheet HTML 2Page - Power Systems GmbH+Co.KG PS-DA0211-02S Datasheet HTML 3Page - Power Systems GmbH+Co.KG PS-DA0211-02S Datasheet HTML 4Page - Power Systems GmbH+Co.KG  
Zoom Inzoom in Zoom Outzoom out
 4 / 4 page
background image
DC-AC INVERTER UNIT
Power Systems – The Power Solution
Web:
www.Power-Systems.de
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Email:
Info@Power-Systems.de
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
All specifications are subject to change without notice.
Page (2)
Version 2.0, 15th August 2007
Thank you very much for usually patronizing Power Systems and TDK’s DC/AC inverter. Following the expansion of it’s use, there
are unexpected troubles that are caused by mis-use or mis-handling because the DC/AC inverter generates a high voltage of
900Vrms or more. Hereafter, the cases of the major troubles are described. Please also refer to “Notes of used” of the attached
paper.
Ex.1 Multilayered PWB
Inverter was mounted the nearest to the main board because there is no surface pattern. However, dielectric breakdown
happened because there was a low-voltage pattern in internal layer, and they were damaged by arc fire.
Ex.2 Foreign body
Short of high voltage area by insect (cockroach etc.) having invaded installed set in food processing plant and counter, etc. Short
by adhesion of metal powder when using it by set such as NC machine tool.
Ex.3 Mechanical stress
Parts will be cracked or the wire of transformer will be broke, etc. When the mechanical stress was given at the installation on the
set.
Ex.4 Storage, handling
When you store it, if the product is piled up or grabed with other inverters together at once, etc. these will be the cause of the
break of transformer’s wire and etc.
1.) Don‘t extand cables.
1.1.) Don‘t cut through nor solder them, unless you have consulted the manufacture.
2.) Don‘t exchange cables.
2.1.) Polarity is very important otherwise -will be able to a short circuit.
-there might be a short circuit.(Please refer to fig.1)
Fig. 1
OK
NG
CABLES CONNECTION


Similar Part No. - PS-DA0211-02S

ManufacturerPart #DatasheetDescription
logo
Power Systems GmbH+Co.K...
PS-DA0211-01 POWER-SYSTEMS-PS-DA0211-01 Datasheet
336Kb / 4P
   DC-AC INVERTER UNIT 12 W DUAL OUTPUTS
PS-DA0211-01S POWER-SYSTEMS-PS-DA0211-01S Datasheet
336Kb / 4P
   DC-AC INVERTER UNIT 12 W DUAL OUTPUTS
PS-DA0211-03 POWER-SYSTEMS-PS-DA0211-03 Datasheet
231Kb / 4P
   DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
PS-DA0211-03S POWER-SYSTEMS-PS-DA0211-03S Datasheet
231Kb / 4P
   DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
PS-DA0211-04 POWER-SYSTEMS-PS-DA0211-04 Datasheet
230Kb / 4P
   DC-AC INVERTER UNIT 12 W DUAL OUTPUTS
More results

Similar Description - PS-DA0211-02S

ManufacturerPart #DatasheetDescription
logo
Power Systems GmbH+Co.K...
PS-DA0211-03 POWER-SYSTEMS-PS-DA0211-03 Datasheet
231Kb / 4P
   DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
PS-DA0284-01 POWER-SYSTEMS-PS-DA0284-01 Datasheet
87Kb / 3P
   DC-AC INVERTER UNIT 11 W DUAL OUTPUTS
PS-DA0276-01-B POWER-SYSTEMS-PS-DA0276-01-B Datasheet
252Kb / 4P
   DC-AC INVERTER UNIT 10 W DUAL OUTPUTS
PS-DA0288-02-X POWER-SYSTEMS-PS-DA0288-02-X Datasheet
204Kb / 4P
   DC-AC INVERTER UNIT 8 W DUAL OUTPUTS
PS-DA0203-01 POWER-SYSTEMS-PS-DA0203-01 Datasheet
404Kb / 4P
   DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
PS-M05D05S3-NJ4L-011 POWER-SYSTEMS-PS-M05D05S3-NJ4L-011 Datasheet
786Kb / 2P
   DC-AC INVERTER UNIT 6,5 W DUAL OUTPUTS
PS-DA0211-01 POWER-SYSTEMS-PS-DA0211-01 Datasheet
336Kb / 4P
   DC-AC INVERTER UNIT 12 W DUAL OUTPUTS
PS-DA0253-02 POWER-SYSTEMS-PS-DA0253-02 Datasheet
377Kb / 4P
   DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
PS-DA0253-11 POWER-SYSTEMS-PS-DA0253-11 Datasheet
348Kb / 4P
   DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
PS-DA0253-13 POWER-SYSTEMS-PS-DA0253-13 Datasheet
365Kb / 4P
   DC-AC INVERTER UNIT 9 W DUAL OUTPUTS
More results


Html Pages

1 2 3 4


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com