1 / 3 page 488 Specifications INPUT Input Voltage 3KW:180-264VAC, single or three phase (<200VAC range limited to 40°C maximum) 4KW:180- 264VAC, three phase (<200VAC range limited to 40°C maximum) Frequency 47-63Hz for both single and three phase input Power Factor 0.95 typical with three phase input 0.98 typical with single phase input ENVIRONMENTAL Operating temperature 0°C to 50° (No De-rating) Storage temperature -40°C to 65°C Cooling Internal fan with over-temperature protection OUTPUT Voltage adjustment Zero to rated output Current adjustment Zero to rated output Ripple & Noise See table Regulation (Line or Load) Voltage: 0.05% of maximum rated output +2mV Current: 0.1% of maximum rated output Transient response Typically recovers in 1ms to within 1% of steady-state output voltage (greater than 50% Vmax) for a 70- 100% or 100-70% load change Stability +/-0.05% of maximum voltage or current over 8 hours after 15 minute warm-up time at fixed line, load and temperature Temperature coefficient 0.02%/°C of maximum output voltage 0.03%/°C of maximum output current DLM Series 3000-4000 WATTS PROGRAMMABLE DC SUPPLY OPERATING Efficiency 5-8V Models: 82% typical 16-80V Models: 87% typical 150-600V Models: 85% typical Remote sense The maximum allowed sense line drop is 2V for 5V, 8V and 16V models and 5V for all other models Remote sense protection Unit will not be damaged due to misconnection of the remote sense leads Remote programming Voltage, current (0-100%) and OVP (5-110%) of full scale can be programmed by selectable 0-5VDC, 0- 10VDC, or 0-5k Ω Remote monitoring Voltage or current can be monitored with user- selectable ranges, 0-5VDC or 0-10VDC Over-voltage protection Crowbar type adjustable from 5-110% rated output using front panel control (local or remote program selectable) Displays and indicators Two 3.5 digital LED displays indicate output voltage, output current and over-voltage setting. LED indication for power on, shut-down, remote, overvoltage, over- temperature and front panel lockout, constant voltage and constant current modes. IEEE-488.2 indicators include error, SRQ and address Software LabVIEW® driver for M9E/M85 (Contact Powerbox) Built-in protection Over-voltage (resets by cycling the Enable/standby switch), over-temperature (will automatically reset) Operational features Master/slave parallel operation, up to 2 units can be connected in parallel with active current sharing control to within 10% of each supply. Series operation, up to 3 units of the same model type can be connected in series (consult manual). Negative terminal rated at 150Vmax Above ground Regulatory compliance CE Mark on all models Features • High power density • Preview push button • Remote voltage sense & remote operation • Calibration without removing covers • Regulatory compliance • Parrallel or series operation • IEEE-488.2 and RS-232 interface options |
Similar Part No. - DLM40-75E |
|
Similar Description - DLM40-75E |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |