Electronic Components Datasheet Search |
|
HDM09-S Datasheet(PDF) 1 Page - HITRON ELECTRONICS CORPORTION |
|
HDM09-S Datasheet(HTML) 1 Page - HITRON ELECTRONICS CORPORTION |
1 / 2 page -19- H HiTRON PCB-MOUNT DC-DC CONVERTER ENCAPSULATED MODULES 9 WATTS SINGLE & DUAL OUTPUT HDM09-S & HDM09-D SERIES FEATURES: LOW COST SINGLE & DUAL OUTPUT 2:1 INPUT RANGE 9W ISOLATED OUTPUT SIX-SIDED METAL SHIELD OUTPUT SPECIFICATION Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Voltage Accuracy: Main O/P ±2.0% typical. Line Regulation: Various with output voltages. ±0.5% typ. Load Regulation: Various with output voltages. Single O/P ±1.0% typical. Dual O/P ±2.0% typical. Noise & Ripple: Typical 100mV for 3.3V/5.0V & 1.0% for others peak to peak. OVP: Built-in on main output. Adjustability: Not available. Overload Protection (OLP): Fully protected against output overload and short circuit. Typical 120-150% max. load. Consult the factory for special OLP setting. SPECIFICATION INPUT SPECIFICATION Input Range: 2:1 DC input range. See Ratings Chart. Input Voltage: Nominal 12/24/48 Vdc. Input Current: Various with input range & load. See Ratings Chart. Input Fuse: Use external fuse. Input Filter: Pi-Network. Isolation Resistance: 1,000 Mega Ohms. Isolation Voltage: 1,500Vdc. EMI: Six-sided metal shielding. GENERAL SPECIFICATION Efficiency: 65-75% typical various with input. Switching Frequency: 40-70K Hz., various with input and loading condition. Circuit Topology: Free Running Flyback Circuit. Transient Response: Peak deviation 200mV. Recovery time < 3mS for a 25% load change. Case: Black coated steel with non-conductive metal base. Power Density: 5.6Watts. / Cubic inch. MTBF: 1,000,000 hours. Mil Std 217, 25°C. Operating Temperature: -10°C to +70°C range. 0°C to +60°C @ full load without derating. From+60°C, derating lineally to half load@ +70°C. (Refer to the Derating Chart). Temperature: -20°C to +85°C. Temperature Coefficient: ± 0.03% /°C. Cooling: Convection cooling up to +60°C @ full load. At least 100LFM moving air is recommended for Full load > +60°C in a confined area. Humidity: Up to 95%RH, Non-condensing. Commercial Grade only. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Line Regulation measured from High to Low Lines at full load. (3) Load Regulation measured from Full Load to 1/2 Full Load at nominal input. (4) Correct fuse size by calculating the max. DC current drain at low Line input & Load and then adding 20-25% for the desired fuse size. Due to requests in market and advances in technology, specifications subject to change without notice. |
Similar Part No. - HDM09-S |
|
Similar Description - HDM09-S |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |