1 / 6 page
110L...-PCB / 430L...-PCB Series
Signal conditioned precision pressure transducers
1/6
January 2007 / 006
www.sensortechnics.com
FEATURES
· 1 to 50 mbar, 1 to 30 "H
2O
gage or differential pressure
(custom calibrations available)
· 1...6 V or 4...20 mA output
· Internal supply regulation
· Precision temperature compensated
and calibrated
· Special calibrations for small volumes
on request
ELECTRICAL CONNECTION
12...24 V
12...36 V
20 mA
10 mA
-25 to 85°C
-10 to 70°C
0 to 50°C
300°C
0 - 80 %RH
SPECIFICATIONS
Maximum ratings
Supply voltage
110L...-PCB
430L...-PCB1
Maximum load current (110L...-PCB only)
source
sink
Temperature limits
Storage
Operating
Compensated
Lead temperature(4 sec soldering)
Humidity limits (pressure inlets only)
SERVICE
Non-corrosive, non-ionic working fluids
such as dry air and dry gases.
1...6 V output version
4...20 mA output version
Scale:
1 cm
1 inch
+Vs
Vout
-Vs
110L...-PCB
V
12 to 24 V
-Vs
430L...-PCB
+Vs
L
V
R
12 to 36 V
GND