3 / 5 page DFB-1310-4X-50SMF-XXX ELECTRICAL-OPTICAL CHARACTERISTICS Parameter Test Conditions Symbol Min. Typ. Max. Units Notes Threshold Current T = 25°C T= TRANGE ITH 10 20 40 mA Operating Current T = 25°C T= TRANGE IOP 45 70 mA 1 Modulation Current T = 25°C T= TRANGE IMOD 25 60 mA ER~4.5dB ER~6.5dB Output Power IF = IOP LOP -4.0 dBm 10km option, 2 +2.5 30km option, 2 Slope Efficiency T = 25°C, SMF η 0.025 mW/mA 10km option 0.1 30km option Extinction Ratio T= TRANGE 6.0 9.0 dB 3 LA (wiggle) LA 1.5 dB 4 Wavelength T = 25°C λ 1290 1330 nm Spectral Width T= TRANGE Δλ 1.0 nm, rms Wavelength temperature coefficient T= TRANGE Δλ/ΔT 0.1 nm/°C Side Mode Suppression T= TRANGE SMSR 30 dB Relative Intensity Noise I=IOP, 20dB ORL, 0.1<F<5.5GHz RIN20 -120 dB/Hz 5 Modulation Bandwidth I=IOP, T=TRANGE I=IOP, T = 25°C S21,3dB 4 6 GHz Rise / Fall Time Tr Tf 90 90 ps 6 Forward Voltage I=IOP, T=TRANGE Vf 1 1.3 V Laser Resistance I=IOP, T=TRANGE RL 2 5 12 Ohms 7 Monitor Current T = 25°C, I=IOP, VB=-2.5V IMON 80 800 μA Tracking Error T=TRANGE TE -1.25 1.25 dB 8 Monitor Dark Current T=TRANGE, VB=-2.5V ID 100 nA Monitor Diode Capacitance VB=-2.5V CMON 10 pF Optical Return Loss ORL 12 dB Unless otherwise stated, all parameters are at TCASE = 25°C, TRANGE, CASE = -40 to 85°C, 2.488 Gbps, PRBS 231-1 Notes: 1. Operating current is the average bias current required to meet the ER, rise/fall, and bandwidth specifications. The target operating condition is 35 mA over threshold at high temperature, 30mA over threshold at RT. 2. Other output power range is possible per customer request. 3. TOSA would be capable of meeting other specifications when modulated over this ER range. 4. Maximum change in power as fiber is rotated by 360º. 5. Measured with an optical receiver with a 3.125 Gb/s filter 6. Rise and fall times are measured 20-80% 7. Resistance is measured between ITH + 10mA and ITH + 20mA 8. Tracking error is defined as the coupled power difference at Tmax or Tmin (relative to 25°C) where the back monitor current, Imon, is held constant at the value found at 25°C at I=Iop. |
Similar Part No. - DFB-1310-4L-50SMF-SCUPC |
|
Similar Description - DFB-1310-4L-50SMF-SCUPC |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |