1 / 2 page WITHSTANDVOLTAGE ISOLATIONRESISTANCE I/P-O/P:3.75KVACI/P-FG:1.88KVACO/P-FG:1.5KVAC I/P-O/P:100MOhms/500VDC/25 /70%RH IP67 SPECIFICATION MODEL CLG-100-12 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48 DCVOLTAGE RATEDCURRENT Note.6 CURRENTRANGE Note.6 RATEDPOWER Note.6 OUTPUT VOLTAGE ADJ.RANGE CURRENT ADJ.RANGE LINEREGULATION LOADREGULATION SETUP,RISETIME HOLDUP TIME (Typ.) VOLTAGERANGE Note.5 FREQUENCY RANGE POWERFACTOR EFFICIENCY (Typ.) ACCURRENT INPUT INRUSHCURRENT(max.) LEAKAGECURRENT SAFETY STANDARDS HARMONICCURRENT EMSIMMUNITY WORKINGTEMP. WORKINGHUMIDITY STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERCURRENT Note.4 OVERVOLTAGE OVERTEMPERATURE 12V 6~12V 15V 7.5~15V 20V 10~20V 24V 12~24V 27V 13.5~27V 36V 18~36V 48V 24~48V 5A 5A 4.8A 4A 3.55A 2.65A 2A 0~5A 0~5A 0~4.8A 0~4A 0~3.55A 0~2.65A 0~2A 60W 75W 96W 96W 95.85W 95.4W 96W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 3.0% 3.0% 3.0% 3.0% 3.0% 2.0% 2.0% Fixed.Canbemodifiedbetween 0%~-15%ratedoutputvoltage Fixed.Canbemodifiedbetween3%~-25%ratedoutputcurrent 1.0% 2.0% 1200ms,80ms/230VAC atfullload 1200ms,80ms/115VAC 60ms/230VAC30 atfullload ms/115VAC 90~264VAC 127~370VDC 47~63Hz PF>0.95/230VACPF>0.95/115VACatfullload 83% 85% 87% 87% 87% 87% 87% 13~16V 16.5~20V 22~27V 27~34V 29~36V 39~48V 52~64V 12V:0.8A/115VAC0.4A/230VAC 15V:0.9A/115VAC0.45A/230VAC20V~48V:1.1A/115VAC0.55A/230VAC COLDSTART 40A/230VAC 0.5mA /240VAC 95~100% Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved UL1310Class2, TUVEN60950-1, UL879(listedinUL SignComponentsManual(SAM)), EN61347-1,EN61347-2-13 CAN/CSA C22.2No.223-M91(exceptfor48V),IP67approved CompliancetoEN55015,EN55022(CISPR22)ClassB Complianceto ClassC(>50%load);EN61000-3-3 EN61000-3-2 CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61547,EN55024,lightindustrylevel(surge4KV),criteria A -30~+70 (Refertooutputloadderatingcurve) 20~90%RH non-condensing -40~+80 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes 301Khrsmin.MIL-HDBK-217F(25 ) 222*68*39mm(L*W*H) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Please refer to OLP characteristics. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. 6. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement of UL1310 class 2. 7. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 . 8. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 1.0Kg;12pcs/13Kg/0.49CUFT Protectiontype: Shutdownandlatchoffo/pvoltage,re-powerontorecover 100WSingleOutputSwitchingPowerSupply Universal AC input / Full range Protections: Short circuit / Overload / Over voltage / Over temperature Built-in active PFC function IP67 design for indoor or outdoor installations UL1310 Class 2 power unit Cooling by free air convection 100% full load burn-in test High Suitable for LED lighting and moving sign applications 3 years warranty (Note.7) reliability Features : C L G - 1 0 0 series RIPPLE&NOISE(max.) Note.2 VOLTAGETOLERANCE Note.3 ENVIRONMENT EMICONDUCTION&RADIATION SAFETY & EMC PROTECTION 90 10 (RTH2) Protectiontype:Shutdowno/pvoltage,re-powerontorecover ( for 48V only) ( except for 48V ) F M M 110 LPS SELV EQUIVALENT CONSTANTCURRENTREGION Note.8 SHORTCIRCUIT Note.4 Hiccupmode,recoversautomaticallyafterfaultconditionisremoved FileName:CLG-100-SPEC2008-12-10 |
Similar Part No. - CLG-100-48 |
|
Similar Description - CLG-100-48 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |