1 / 2 page V-Infinity, LLC, 9615 SW Allen Blvd Suite 103, Beaverton, OR 97005 www.v-infinity.com 1-866-372-1258 • VQP-100-3D Switching Power Supply CH1 CH2 CH3 CH4 DC output voltage 5V 3.3V 24V -12V Output V. tolerance ±3% ±3% ±6% ±5% Output rated current 8A 8A 1.3A0 0.6A Output current range 2-10A 0-10A 0.3-2A 0-1A Ripple & noise p-p 100mV 100mV 150mV 150mV Line regulation ±1% ±1% ±2% ±1% Load regulation ±2% ±2% ±6% ±2% Max. output power 100.6W Efficiency 75% DC voltage adj. CH1,2: +10, -5% Input voltage range 90~264VAC 47~63Hz; 120-370VDC AC current 1.5A/115V 0.75A/230V Inrush current cold start<= 40A/230V Leakage current <3.5mA/240VAC Overload protection 105%~150%, pulsing (hiccup mode), auto restart. Over voltage protection CH1:5.75~6.75V CH2:3.8~4.4V type: shutdown reset: re-power on Over temp. protection 95°C±5°C TSW1 type: shutdown reset: auto recovery Temperature coefficient ±0.3%/ °C(0~50°C) Set up, rise, hold up time 800ms, 50ms, 16ms / 115, 230VAC Power factor PF>0.95/230VAC, PF>0.98/115VAC Vibration 10~500Hz, 2G 10 min./1 cycle, period fo 60 min. each axes Withstand voltage I/P-O/P: 3KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC for 1 min. Isolation resistance I/P-O/P, I/P-FG, O/P-FG: 500VDC / 100M Ohms min. Working temp., humidity -10°C~+60°C (refer to output derating curve), 20%-90% RH Storage temp., humidity -20°C~+85°C, 10%-95% RH Dimensions 7.83x3.9x1.97 inches (199x99x50mm) case: 916A Weight 1.61lbs (730gs) Safety standards UL1950, TUV EN60950 approved EMC standards EN55022 class B, EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-3-2,-3, EN55024 verification Notes: 1. All parameters are specified at 230VAC input, rated load, 25°C 70% RH ambient 2. Tolerance includes set up tolerance, line regulation, load regulation 3. Ripple & noise are measured at 20MHz by using a 12” twisted pair terminated with a 0.1uF & 47 uF capacitor 4. Line regulation is measured from low line to high line at rated load 5. Load regulation is measured from 20% to 100% rated load, and other outputs at 60% rated load. 6. Each output provides up to maximum current, but total load can not exceed max. output power. V-Infinity reserves the right to make changes to its products or to discontinue any product or service without notice, and to advise customers to verify the most up-to-date product information before placing orders. V-Infinity assumes no liability or responsibility for customer ’s applications using V-Infinity products other than repair or replacing (at V-I’s option) V-Infinity products not meeting V-I’s published specifications. Nothing will be covered outside of standard product warranty. Features ·Universal AC input / Full range ·Built-in active PFC function, PF>0.95 ·Protections:Short circuit/Over load/Over voltage ·Free air cooling convection ·CH4: Polarity is selectable ·Fixed switching frequency at 100KHz(Optional) ·3 year warranty |
Similar Part No. - VQP-100-3D |
|
Similar Description - VQP-100-3D |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |