144
Rated voltage
275 VAC 50/60 Hz (ENEC)
280 VAC 50/60 Hz (UL, CSA)
Capacitance range
0.01 – 10.0 µF
Capacitance tolerance
± 20% standard, ± 10% option, ± 5% on request
Temperature range
–55 to +105°C
Climatic category
55/105/56/B
Approvals
ENEC, UL, CSA
Dissipation factor
Maximum values at +23°C
C
≤ 0.1 µF
0.1µF < C
≤ 1 µF
C > 1 µF
1 kHz
0.1%
0.1%
0.1%
10 kHz
0.2%
0.4%
0.8%
100 kHz
0.6%
––
Test voltage between
The 100% screening factory test is carried
terminals
out at 2200 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards. All
electrical characteristics are checked
after the test.
Insulation resistance
C
≤ 0.33 µF: ≥ 30 000 M
Ω
C > 0.33 µF:
≥ 10 000 s
In DC applications
Maximum voltage 630 VDC
PHE840M
• EMI suppressor, class X2, metallized polypropylene
• 0.01 – 10.0 µF, 275/280 VAC, +105°C
• New, small dimensions including low profile capacitors
• Replaces PHE843
TYPICAL APPLICATIONS
CONSTRUCTION
TECHNICAL DATA
For worldwide use as electromagnetic
interference suppressor in all X2 and
across-the-line applications.
Metallized polypropylene film encapsulated
with selfextinguishing epoxy resin in a box of
material recognized to UL 94 V–0.
p
d
std l
max l
b
7.5 ± 0.4
0.6
17
20
±0.4
10.0 ± 0.4
0.6
17
30
±0.4
15.0 ± 0.4
0.8
17
30
±0.4
22.5 ± 0.4
0.8
6
30
±0.4
27.5 ± 0.4
0.8
6
30
±0.4
37.5 ± 0.5
1.0
6
30
±0.7
Tolerance in lead length
< 30 mm
mm
≥ 30 mm
mm
+0
–1
+5
–0
L
H
B
p
l
∅ d
0.5
b
ENVIRONMENTAL TEST DATA
Endurance
IEC 60384–14
1.25 x U
R VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
3 directions at 2 hours each,
No visible damage
Test Fc
10–55 Hz at 0.75 mm or 98 m/s2
No open or short circuit
Bump
IEC 60068–2–29
1000 bumps at
No visible damage
Test Eb
390 m/s2
No open or short circuit
Change of temperature
IEC 60068–2–14
Upper and lower rated
No visible damage
Test Na
temperature 5 cycles
Active flammability
EN 132400
Passive flammability
IEC 60384-14 (1993)
Enclosure material of
EN 132400
UL94V–0 flammability class
UL1414
Humidity
IEC 60068-2-3
+40°C and
56 days
Test Ca
90 – 95% R.H.