8 / 13 page
CY23EP09
Document #: 38-07760 Rev. *B
Page 8 of 13
25
50
75
100
125
150
175
200
33
66
100
133
166
200
233
Frequency (MHz)
15pF, -45C, Standard Drive
15pF, 90C, Standard Drive
30pF, -45C, Standard Drive
30pF, 90C, Standard Drive
15pF, -45C, High Drive
15pF, 90C, High Drive
30pF, -45C, High Drive
30pF, 90C, High Drive
Figure 3. 3.6V Measured Supply Current versus Frequency, Drive Strength, Loading, and Temperature. Note that the
30-pF data above 100 MHz is beyond the data sheet specification of 22 pF.
20
40
60
80
100
120
33
66
100
133
166
200
Frequency (MHz)
15pF, -45C, Standard Drive
15pF, 90C, Standard Drive
15pF, -45C, High Drive
15pF, 90C, High Drive
30pF, -45C, High Drive
30pF, 90C, High Drive
Figure 4. 2.7V Measured Supply Current versus Frequency, Drive Strength, Loading, and Temperature. Note that the
30-pF high-drive data above 100bMHz is beyond the data sheet specification of 22 pF.