1 / 4 page
HRS2(H) Relay
1.COIL DATA
1-1.Nominal Voltage
3 VDC to 24 VDC
1-2.Coil Resistance
Refer to Table 1
1-3.Operate Voltage
Refer to Table 1
1-4.Release Voltage
Refer to Table 1
1-5.Nominal Power Consumption
150 to 360 mW
2.CONTACT DATA
2-1.Contact Arrangement
2 Form C
2-2.Contact Material
AuAg
2-3.Contact Rating
1A 24 VDC / 120VAC
2-4.Max. Switching Voltage
60 VDC / 120 VAC
2-5.Max. Switching Current
2A
2-6.Max. Switching Power
60 VA , 24W
2-7.Contact Resistance ( Initial )
100 mฆธ. at 6 VDC 1A
Electrical
100,000 operations at nominal load
2-8.Life Expectancy
Mechanical
10,000,000 operations
3.GENERAL DATA
3-1.Insulation Resistance
Min.100Mฆธ at 500 VDC
3-2.Dielectric Strength
1,000VAC , 1min between open contact
1,500VAC , 1min between contact and coil
3-3.Surge Strength
2,000 VAC ( 20 ฆฬs )
3-4.Operate Time
Max. 6ms
3-5.Release Time
Max. 4ms
3-6.Temperature Range
-30 to +60 กๆ
3-7.Shock Resistance
15G
3-8.Vibration Resistance
10 - 55 Hz , Amplitude 1.5mm
3-9.Weight
5 gr.
3-10.Safety Standard
UL NO. E164730
CSA NO. LR109368