2 / 4 page NET1 AC-DC Series Data Sheet MAY 18, 2005 revised to APR 05, 2006 Page 2 of 4 www.power-one.com Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 240 watts. 20 ms Input Current 85 VAC at full rated load. 4.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 220 VAC, one cycle, 25 °C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 75 % Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power With 300 LFM forced air cooling. (Note 1) 240 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified. See Model Selection Charts input range, changes in load starting at 20% load and changing to 100% load. Transient Response Recovery time, to within 1% of initial set point due to a 10-100% load change, 500 µs 1% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 2 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN TYP MAX UNITS Overvoltage Protection Overvoltage protection on all outputs. 120 140 % Unit latches off when overvoltage is detected. AC input must be recycled to reset. Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. All outputs are individually current limited. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good Signal indicates output good when at a TTL high state. If any of the outputs are <14% or >14% of the nominal output voltage, then this signal will make a transition to a TTL low state. Pull-up resistance is 1k to 5V Vcc and minimum sink current is 50 mA. Maximum voltage at low state is 0.5 V. Input Power Fail Warning TTL-compatible signal. Pull-up resistance is 1k to 5V Vcc and minimum sink current is 50 mA. Maximum voltage at low state is 0.5 V. Time before regulation 5 ms dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. Current Share Available on all outputs. Accuracy of shared current with up to 6 parallel units. 10 % Single wire current share. Isolation diodes need to be added for parallel configurations with or without redundancy. Remote Sense Available on all outputs. Total voltage compensation for cable losses with 500 mV respect to the main output. NOTES: 1) Output current ratings are expressed with 300 LFM forced air @ 18 CFM. |
Similar Part No. - NET1-4130 |
|
Similar Description - NET1-4130 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |