Electronic Components Datasheet Search |
|
MPU150-4000 Datasheet(PDF) 2 Page - Power-One |
|
MPU150-4000 Datasheet(HTML) 2 Page - Power-One |
2 / 6 page MPU150/MDU150 Series Data Sheet JUN 08, 2006 revised to JUL 14, 2006 Page 2 of 6 www.power-one.com Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER Metric Mounting Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262. RoHS lead solder exemption No RoHS suffix character required. RoHS compliant for all 6 substances Add “G” as the last character of the part number. DC Input Model Selection - 150W WITH 300 LFM FORCED-AIR COOLING ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS MODEL OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY +3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V MDU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V +12V N/A 2A 0.4% 3% 1% 11.76V to 12.24V +5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V MDU150-4000 +12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V +2.5V 2.25V to 3.0V 30A (Note 3) 2% 2% 2% 2.49V to 2.51V MDU150-4230 +3.3V 3.15V to 3.8V 15A (Note 3) 1.5% 1.5% 1.5% 3.28V to 3.32V 12V 10.8V to 13.2V 3A 1% 1% 1% 11.94V to 12.06V 5V 5.0V to 5.5 V 2A 1% 1% 1% 4.98V to 5.0V +3.3V 3.15V to 3.8V 30A (Note 5) 1.5% 1.5% 1% 3.28V to 3.32V MDU150-4350 +5V 5.0V to 5.5V 15A (Note 5) 1% 1% 1% 5.00V to 5.04V 12V 10.8V to 13.2V 3A (Note 4) 7% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 4) 7% 7% 1% 11.94V to 12.06V +5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V MDU150-4530 +3.3V 3.15V to 3.60V 15A (Note 3) 0.6% 1.5% 1.5% 3.28V to 3.32V 12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V 12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V3 and V4 is 5A, maximum rating. 2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V1 and V2 is 40A, maximum rating. 3) Total current between V1 and V2 is 30A, maximum rating. MPU150 Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC input. 47 63 Hz Hold-up Time After last AC line peak at 150 watts. MPU150-4350 17.5 ms All other models 20 Input Current 85 VAC at full rated load. MPU150 3.0 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. 100 120 Switching frequency of secondary transformer. 65 90 kHz Switching frequency of Power Factor Correction circuit. 60 |
Similar Part No. - MPU150-4000 |
|
Similar Description - MPU150-4000 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |